🩺 NIC Health: cross-site comparison (SITE1 · SITE2)

Generated by nic-report v2.16.0 — © 2026 Ciro Iriarte · 2026-10-27 20:30:01 +00:00

1. Executive summary

SiteHostsClean (of collected)Hosts CRIT / WARN / UNKNOWNStatusActions P1 / P2 / P3 / P4
SITE132 (66.7%)1 / 0 / 0🔴 CRIT1 / 0 / 0 / 0
SITE230 (0.0%)0 / 2 / 0🟡 WARN0 / 1 / 0 / 0

Top recommendations (all 2 in section 7, with their rules)

Every finding is explained by a recommendation.

2. Coverage and comparability

SITE1SITE2
Hosts33
Collected32
Rolescmp1×2, ctrl1×1stor1×3
NIC ASICs / ports3 / 122 / 8
Ports with link128
Deep checks evaluated2416
FEC in useFirecode FEC 12Firecode FEC 8
nic-health version2.14.02.14.0
Typed metrics / impact facts3 of 3 / 32 of 2 / 2
Hosts with nic-xray32
Optics from deep / nic-xray / none12 / 0 / 08 / 0 / 0
Window30 s30 s
Collected on2026-10-272026-10-27

Hosts not collected

SiteHostStatusExitProblem
SITE2acme-s2-stor1-03ssh-fail255—

3. Verdicts

SiteHostsCollectedOKWARNCRITUNKNOWNClean (of collected)CRIT / WARN / UNKNOWN rows
SITE133201066.7%1 / 1 / 0
SITE23202000.0%0 / 4 / 0

SITE1 by role

RoleHostsOKWARNCRITUNKNOWNClean (of collected)
cmp12101050.0%
ctrl111000100.0%

SITE2 by role

RoleHostsOKWARNCRITUNKNOWNClean (of collected)
stor1302000.0%

4. Findings

SITE1 · acme-s1-cmp1-01

SITE2 · acme-s2-stor1-01

SITE2 · acme-s2-stor1-02

5. Baselines and outliers

Over ports with link. Baseline: the sites in this report (SITE1, SITE2; 20 ports with an Rx reading).

5.1 Receive power by module type

Module typePortsMinp5MedianMax
100GBASE-SR4 or 25GBASE-SR20-8.60-0.81-0.74-0.60

5.2 Receive power outliers

At least the configured margin below the median for the module type, with a robust score (median/MAD) of at least 3.5.

HostPortRoleModule typeRx dBmMedianΔ dBRobust z
SITE1 acme-s1-cmp1-01eth0cmp1100GBASE-SR4 or 25GBASE-SR-8.60-0.74-7.9-75.7

Within 3 dB of the module's own low limit: SITE1 acme-s1-cmp1-01 eth0 (-8.60 dBm, limit -11.3).

5.3 Transmit power by module type

Module typePortsMinMedianMax
100GBASE-SR4 or 25GBASE-SR20-1.00-1.00-1.00

5.4 Link errors since boot

Uncorrectable symbol errors (rx_symbol_err_phy) since boot.

HostPortRoleSymbol errorsIn windowPer hour of uptime
SITE1 acme-s1-cmp1-01eth0cmp1414,877,072943750,000

5.5 Link stability

No port above the carrier-change threshold.

5.6 Receive discards since boot

HostPortRoleDiscardsIn window
SITE2 acme-s2-stor1-01eth0stor112,818,1881
SITE2 acme-s2-stor1-02eth0stor19,132,2101

5.7 Module temperature and PCIe

Hottest modules: SITE1 acme-s1-cmp1-01 eth0 40 °C, SITE1 acme-s1-cmp1-01 eth1 40 °C, SITE1 acme-s1-cmp1-01 eth2 40 °C, SITE1 acme-s1-cmp1-01 eth3 40 °C, SITE1 acme-s1-cmp1-02 eth0 40 °C. No module within 10 °C of its own high limit.

HostASICRoleTrainedSupported
SITE2 acme-s2-stor1-010000:01:00stor12.5 GT/s x416.0 GT/s x4 (slot)
SITE2 acme-s2-stor1-020000:01:00stor12.5 GT/s x416.0 GT/s x4 (slot)

6. Patterns

Within a site: the same issue on the same port or ASIC in two or more hosts of a role.

SiteRoleIssuePort / ASICHosts
SITE2stor1generic.pcie.link0000:01:002 of 2: acme-s2-stor1-01, acme-s2-stor1-02
SITE2stor1mlx5.nic.discardseth02 of 2: acme-s2-stor1-01, acme-s2-stor1-02

No issue repeats on the same role at two or more sites.

7. Recommended actions (priority order)

Rule catalogs: nic-report-rules.json (catalog 2026.10.4, 19 rules). Ranked by priority (P1 act now … P4 informational) after modifiers and service impact, then activity in the window, number of hosts and place. Matches on one target are merged into one recommendation that cites every rule.

7.1 Unexplained, needs review

None: every finding is covered by a recommendation.