Power Sync with the Compute Service
===================================

Baremetal Power Sync
====================
Each Baremetal conductor process runs a periodic task which synchronizes the
power state of the nodes between its database and the actual hardware. If the
value of the :oslo.config:option:`conductor.force_power_state_during_sync`
option is set to ``true`` the power state in the database will be forced on
the hardware and if it is set to ``false`` the hardware state will be forced
on the database. If this periodic task is enabled, it runs at an interval
defined by the :oslo.config:option:`conductor.sync_power_state_interval` config
option for those nodes which are not in maintenance.

Compute-Baremetal Power Sync
============================
Each ``nova-compute`` process in the Compute service runs a periodic task which
synchronizes the power state of servers between its database and the compute
driver. If enabled, it runs at an interval defined by the
`sync_power_state_interval` config option on the ``nova-compute`` process.
In case of the compute driver being baremetal driver, this sync will happen
between the databases of the compute and baremetal services. Since the sync
happens on the ``nova-compute`` process, the state in the compute database
will be forced on the baremetal database in case of inconsistencies. Hence a
node which was put down using the compute service API cannot be brought up
through the baremetal service API since the power sync task will regard the
compute service's knowledge of the power state as the source of truth. In order
to get around this disadvantage of the compute-baremetal power sync,
baremetal service does power state change callbacks to the compute service
using external events.

Power State Change Callbacks to the Compute Service
---------------------------------------------------

Whenever the Baremetal service changes the power state of a node, it can issue
a notification to the Compute service. The Compute service will consume this
notification and update the power state of the instance in its database.
By conveying all the power state changes to the compute service, the baremetal
service becomes the source of truth thus preventing the compute service from
forcing wrong power states on the physical instance during the
compute-baremetal power sync. It also adds the possibility of bringing
up/down a physical instance through the baremetal service API even if it was
put down/up through the compute service API.

This change requires the :oslo.config:group:`nova` section and the necessary
authentication options like the :oslo.config:option:`nova.auth_url` to be
defined in the configuration file of the baremetal service. If it is not
configured the baremetal service will not be able to send notifications to the
compute service and it will fall back to the behaviour of the compute service
forcing power states on the baremetal service during the power sync.
See :oslo.config:group:`nova` group for more details on the available config
options.

In case of baremetal stand alone deployments where there is no compute service
running, the :oslo.config:option:`nova.send_power_notifications` config option
should be set to ``False`` to disable power state change callbacks to the
compute service.

.. note::
    The baremetal service sends notifications to the compute service only if
    the target power state is ``power on`` or ``power off``. Other error
    and ``None`` states will be ignored. In situations where the power state
    change is originally coming from the compute service, the notification
    will still be sent by the baremetal service and it will be a no-op on the
    compute service side with a debug log stating the node is already powering
    on/off.

.. note::
    Although an exclusive lock is used when sending notifications to the
    compute service, there can still be a race condition if the
    compute-baremetal power sync happens to happen a nano-second before the
    power state change event is received from the baremetal service in which
    case the power state from compute service's database will be forced on the
    node.