                                                  ZyXEL Communications Corp.
                                                    edited by Manfred Recla
                                                             April 23, 1997

                Release Note on Omni TA128 Version 2.02d
                =========================================
                          for DSS1 and 1TR6

Fixed Bugs:
-----------
 1. The information element is not correct in LLC for data call.
 2. In CAPI mode, while TA making a call, it will crash.

New Implementation:
-------------------
 1. ATI11 : display PPP status.
 2. BACP support new ID & old ID.




----------------------------------------------------------------------------



                                                             April 18, 1997

                Release Note on Omni TA128, Version 2.02c
               =========================================
                     for alpha-test group only !


Fixed Bugs:
----------
 1. Issue 'AT&D1' to dial default number function while the stored number is
    Axxx or Bxxx, then TA may not dial out while second DTR is off.
 2. While one B channel connect in data ( data call ) and another B channel
    connect in voice ( phone call ), dropping the phone call may cause the
    data call to disconnect sometimes.
 3. The setting of DTE port 2 should load factory default value. The default
    outgoing protocol is PPP.
 4. For 1TR6 version, the value of item 'Cause' while issuing 'ATI3' is not
    correct sometimes.
 5. V.110/38k4-8n1 compatibility problem with "CITAM" ISDN-TA. The German
    product "CITAM" uses another version of Siemens V.110 chip. About the
    setting of "CITAM": XX-bit should be set to "IGNORE" because this setting
    is normal V.110 configuration; "INBAND REMOTE SUPERVISOR" should be set
    to "OFF" because Omni TA128 does not yet have implemented the IPE
    function of V.110.

New Implementation:
-------------------
 1. phone call disable function.
    s120.0= 0   enable POTS prot 1 call out.
            1   disable POTS port 1 call out.
    s120.1= 0   enable POTS port 2 call out.
            1   disable POTS port 2 call out.
 2. Supplementary service in a/b adapter for Italy, please use the following
    command to do the service:
   2.1 HOLD - Flash/7
       The service allows the user that keeping busy in a call, holding-on
       the call and making a call to a new user, utilizing the same B channel.
       The user can talk by turns to each connected users, or resume the
       normal call status by release the active connection.
   2.2 RETRIEVE  - Flash/8
       The service allows the user to connect the call that was holded-on
       previously. The user can switch between two call in same B-channel by
       utilizing HOLD and RETRIEVE appropriately - HOLD-on active connection
       ans then RETRIEVE another call.
   2.3 CONFERENCE - Flash/9
       The service allows the user, during an hold-on call with two users, to
       switch the state of simultaneous speech with both users, utilizing the
       same B channel. Then the user can come back to the hold-on state or
       disconnected both the connections.