    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2024-7847",
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "state": "PUBLISHED",
        "assignerShortName": "Rockwell",
        "dateReserved": "2024-08-15T15:51:22.233Z",
        "datePublished": "2024-10-14T13:47:14.540Z",
        "dateUpdated": "2024-10-15T14:05:45.670Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "RSLogix 500®",
                    "vendor": "Rockwell Automation",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "All"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "RSLogix™ Micro Developer and Starter",
                    "vendor": "Rockwell Automation",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "All"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "RSLogix™ 5",
                    "vendor": "Rockwell Automation",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "All"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "reporter",
                    "value": "Sharon Brizinov of Claroty Research - Team82"
                }
            ],
            "datePublic": "2024-09-19T13:00:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<p><b>VULNERABILITY DETAILS</b></p><p>Rockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. </p><p>A feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention.  This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.</p>"
                        }
                    ],
                    "value": "VULNERABILITY DETAILS\n\nRockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. \n\nA feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention.  This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability."
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-19",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-19 Embedding Scripts within Scripts"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "HIGH",
                        "attackRequirements": "NONE",
                        "attackVector": "LOCAL",
                        "baseScore": 8.8,
                        "baseSeverity": "HIGH",
                        "privilegesRequired": "NONE",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "HIGH",
                        "subConfidentialityImpact": "HIGH",
                        "subIntegrityImpact": "HIGH",
                        "userInteraction": "PASSIVE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "HIGH",
                        "vulnConfidentialityImpact": "HIGH",
                        "vulnIntegrityImpact": "HIGH",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                },
                {
                    "cvssV3_1": {
                        "attackComplexity": "HIGH",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 7.7,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "CHANGED",
                        "userInteraction": "REQUIRED",
                        "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-345",
                            "description": "CWE-345 Insufficient Verification of Data Authenticity",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
                "shortName": "Rockwell",
                "dateUpdated": "2024-10-14T13:47:14.540Z"
            },
            "references": [
                {
                    "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1701.html"
                }
            ],
            "source": {
                "discovery": "EXTERNAL"
            },
            "title": "RSLogix™ 5 and RSLogix 500® Remote Code Execution Via VBA Embedded Script",
            "workarounds": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<p><b>Mitigations and Workarounds </b></p><p>Users using the affected software are encouraged to apply the following mitigations and security best practices, where possible. </p><p>· &nbsp; &nbsp; &nbsp; Deny the execution feature in FactoryTalk® Administration Console, when not needed, by navigating to “Policies”, selecting ‘”Enable/Disable VBA”, and then checking the “Deny” box to block VBA code execution.</p><p>· &nbsp; &nbsp; &nbsp; Save project files in a Trusted® location where only administrators can modify it and verify file integrity.</p><p>· &nbsp; &nbsp; &nbsp; Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password.</p>"
                        }
                    ],
                    "value": "Mitigations and Workarounds \n\nUsers using the affected software are encouraged to apply the following mitigations and security best practices, where possible. \n\n·       Deny the execution feature in FactoryTalk® Administration Console, when not needed, by navigating to “Policies”, selecting ‘”Enable/Disable VBA”, and then checking the “Deny” box to block VBA code execution.\n\n·       Save project files in a Trusted® location where only administrators can modify it and verify file integrity.\n\n·       Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password."
                }
            ],
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "affected": [
                    {
                        "vendor": "rockwellautomation",
                        "product": "rslogix_500",
                        "cpes": [
                            "cpe:2.3:a:rockwellautomation:rslogix_500:*:*:*:*:*:*:*:*"
                        ],
                        "defaultStatus": "unknown",
                        "versions": [
                            {
                                "version": "0",
                                "status": "affected",
                                "lessThan": "*",
                                "versionType": "custom"
                            }
                        ]
                    },
                    {
                        "vendor": "rockwellautomation",
                        "product": "rslogix_micro_developer",
                        "cpes": [
                            "cpe:2.3:a:rockwellautomation:rslogix_micro_developer:*:*:*:*:*:*:*:*"
                        ],
                        "defaultStatus": "unknown",
                        "versions": [
                            {
                                "version": "0",
                                "status": "affected",
                                "lessThan": "*",
                                "versionType": "custom"
                            }
                        ]
                    },
                    {
                        "vendor": "rockwellautomation",
                        "product": "rslogix_micro_starter",
                        "cpes": [
                            "cpe:2.3:a:rockwellautomation:rslogix_micro_starter:*:*:*:*:*:*:*:*"
                        ],
                        "defaultStatus": "unknown",
                        "versions": [
                            {
                                "version": "0",
                                "status": "affected",
                                "lessThan": "*",
                                "versionType": "custom"
                            }
                        ]
                    },
                    {
                        "vendor": "rockwellautomation",
                        "product": "rslogix_5",
                        "cpes": [
                            "cpe:2.3:a:rockwellautomation:rslogix_5:*:*:*:*:*:*:*:*"
                        ],
                        "defaultStatus": "unknown",
                        "versions": [
                            {
                                "version": "0",
                                "status": "affected",
                                "lessThan": "*",
                                "versionType": "custom"
                            }
                        ]
                    }
                ],
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2024-10-14T15:18:18.670939Z",
                                "id": "CVE-2024-7847",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-10-15T14:05:45.670Z"
                }
            }
        ]
    }
}