{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2024-6325",
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "state": "PUBLISHED",
        "assignerShortName": "Rockwell",
        "dateReserved": "2024-06-25T15:13:41.907Z",
        "datePublished": "2024-07-16T16:43:44.494Z",
        "dateUpdated": "2024-08-01T21:33:05.423Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "FactoryTalk® System Services (installed via FTPM)",
                    "vendor": "Rockwell Automation",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "6.40"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "FactoryTalk® Policy Manager (FTPM)",
                    "vendor": "Rockwell Automation",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "v6.40"
                        }
                    ]
                }
            ],
            "datePublic": "2024-07-11T13:00:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">The v6.40 release of Rockwell Automation FactoryTalk® Policy Manager</span><a target=\"_blank\" rel=\"nofollow\">&nbsp;allowed </a><span style=\"background-color: rgb(255, 255, 255);\">the private keys to be insecurely stored with read and execute privileges for the Windows group, ‘Everyone’. These keys are used to generate digital certificates and pre-shared keys. This vulnerability could allow a malicious user with access to the machine to obtain private keys. If obtained, a malicious user could impersonate resources on the secured network. </span><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\">For customers</a><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;using FactoryTalk® Policy Manager v6.40 who mitigated</span><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\">&nbsp;</a><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html\">CVE-2021-22681</a><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;and </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html\">CVE-2022-1161</a><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;by implementing CIP security and did not update to the versions of the software</span><a target=\"_blank\" rel=\"nofollow\">&nbsp;</a><span style=\"background-color: rgb(255, 255, 255);\">that contain the remediation, this vulnerability could allow a threat actor to exploit </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html\">CVE-2022-1161</a><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;and </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html\">CVE-2022-1161.</a>\n\n"
                        }
                    ],
                    "value": "The v6.40 release of Rockwell Automation FactoryTalk® Policy Manager CVE-2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html  and  CVE-2022-1161 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html  by implementing CIP security and did not update to the versions of the software CVE-2022-1161 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html  and  CVE-2022-1161. https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1585.html"
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-122",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-122 Privilege Abuse"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "attackVector": "LOCAL",
                        "baseScore": 6,
                        "baseSeverity": "MEDIUM",
                        "privilegesRequired": "LOW",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "NONE",
                        "subConfidentialityImpact": "HIGH",
                        "subIntegrityImpact": "NONE",
                        "userInteraction": "NONE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "NONE",
                        "vulnConfidentialityImpact": "NONE",
                        "vulnIntegrityImpact": "NONE",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-269",
                            "description": "CWE-269 Improper Privilege Management",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
                "shortName": "Rockwell",
                "dateUpdated": "2024-07-16T16:43:44.494Z"
            },
            "references": [
                {
                    "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1678.html"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<p>Users using the affected software are encouraged to implement the following steps to invalidate the existing vulnerable private keys/digital certificates and regenerate new secure ones.</p><p><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\">· &nbsp; &nbsp; &nbsp; Clear CIP Security configurations from devices and from FactoryTalk® Policy Manager</a></p><p>· &nbsp; &nbsp; &nbsp; Update FactoryTalk® System Services and FactoryTalk® Policy Manager to v6.40.01</p><p>· &nbsp; &nbsp; &nbsp; Redeploy CIP Security Policy </p><p>Detailed steps are below <b>(FactoryTalk System Services (FTSS) is updated through the installation of FactoryTalk Policy Manager (FTPM)</b></p><p>1) &nbsp; &nbsp;  Remove deployed security policy from all devices using FactoryTalk® Policy Manager (FTPM):</p><p>a. &nbsp; &nbsp; &nbsp; Open FTPM.</p><p>b. &nbsp; &nbsp; &nbsp; Document all Zone’s security settings and all Conduit’s settings as you must re-create them after updating FTPM.</p><p>c. &nbsp; &nbsp; &nbsp; Change all devices port’s Policies &gt; Zone values to the “Unassigned” Zone.</p><p>d. &nbsp; &nbsp; &nbsp; Delete all zones and conduits.</p><p>e. &nbsp; &nbsp; &nbsp; Deploy (CIP).  Ensure that all endpoints were reset successfully.</p><p>f. &nbsp; &nbsp; &nbsp;  [migrating from v6.40 only] Deploy (OPC UA).  Ensure all endpoints were reset successfully.</p><p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;  i. &nbsp; &nbsp;  For any OPC UA clients, perform whatever steps are required by those clients to remove the previously applied certificates.</p><p>g. &nbsp; &nbsp; &nbsp; Close FTPM</p><p>2) &nbsp; &nbsp;  Delete the \\FTSS_backup folder:</p><p>a. &nbsp; &nbsp; &nbsp; c:\\ProgramData\\Rockwell\\RNAServer\\Global\\RnaStore\\FTSS_Backup</p><p>3) &nbsp; &nbsp;  Delete the \\keystore folder:</p><p>a. &nbsp; &nbsp; &nbsp; c:\\ProgramData\\Rockwell Automation\\FactoryTalk System Services\\keystore</p><p>4) &nbsp; &nbsp;  Delete any backup copies of the \\keystore folder.  They will be named the same as the \\keystore folder but with a suffix appended to it, like:</p><p>a. &nbsp; &nbsp; &nbsp; c:\\ProgramData\\Rockwell Automation\\FactoryTalk System Services\\ keystore_source_2024_04_25_12_25_38_541566</p><p>5) &nbsp; &nbsp;  Delete the PSKs.json file:</p><p>a. &nbsp; &nbsp; &nbsp; c:\\ProgramData\\Rockwell Automation\\FactoryTalk System Services\\PSKs.json</p><p>6) &nbsp; &nbsp;  Delete any backup copies of the PSKs.json file.  They will be named the same as the PSKs.json file but with a suffix appended to it, like:</p><p>a. &nbsp; &nbsp; &nbsp; c:\\ProgramData\\Rockwell Automation\\FactoryTalk System Services\\ PSKs.json_source_2024_05_17_07_38_25_200356</p><p>7) &nbsp; &nbsp;  Install FactoryTalk® Policy Manager version 6.40.01.</p><p>a. &nbsp; &nbsp; &nbsp; Restart the computer when prompted at the end of the install.</p><p>8) &nbsp; &nbsp;  Open FTPM.  FTPM will attempt to connect to the FactoryTalk® System Services web server before proceeding.</p><p>9) &nbsp; &nbsp;  If FTPM could not successfully connect to FactoryTalk® System Services (FTSS), it is because the FTSS service hasn’t started yet.  It will eventually start or else you can start the FTSS service manually in Windows Services.</p><p>10) &nbsp; Re-create the original Zones.</p><p>11) &nbsp; Move the devices from the unassigned Zone back to their original zones.</p><p>12) &nbsp; Re-create the original Conduits.</p><p>13) &nbsp; Deploy (CIP endpoints).</p><p>14) &nbsp; [migrating from v6.40 only] Deploy (OPC UA endpoints).</p><p>a. &nbsp; &nbsp; &nbsp; For any OPC UA client endpoints, manually apply the newly generated certificates from this deploy.</p><p>Additionally, we encourage customers to implement our suggested security best practices to minimize the risk of vulnerability.</p><p>· &nbsp; &nbsp; &nbsp; <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">Security Best Practices</a></p>\n\n<br>"
                        }
                    ],
                    "value": "Users using the affected software are encouraged to implement the following steps to invalidate the existing vulnerable private keys/digital certificates and regenerate new secure ones.\n\n Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
                }
            ],
            "source": {
                "advisory": "SD1678",
                "discovery": "INTERNAL"
            },
            "title": "Rockwell Automation Unsecured Private Keys in FactoryTalk® System Services",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2024-07-16T18:04:54.518272Z",
                                "id": "CVE-2024-6325",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-07-17T15:47:32.018Z"
                }
            },
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-01T21:33:05.423Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1678.html",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}