    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2024-4192",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2024-04-25T14:55:16.868Z",
        "datePublished": "2024-04-30T23:01:58.874Z",
        "dateUpdated": "2024-09-03T18:16:25.046Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "CNCSoft-G2 DOPSoft",
                    "vendor": "Delta Electronics",
                    "versions": [
                        {
                            "lessThanOrEqual": "Versions 2.0.0.5 (with DOPSoft v5.0.0.93)",
                            "status": "affected",
                            "version": " 0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "value": "Natnael Samson working with Trend Micro Zero Day Initiative reported this vulnerability to CISA."
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<span style=\"background-color: rgb(241, 241, 242);\">Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.</span>\n\n"
                        }
                    ],
                    "value": "\nDelta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.\n\n"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 7.8,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "REQUIRED",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-121",
                            "description": "CWE-121 Stack-based Buffer Overflow",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2024-04-30T23:01:58.874Z"
            },
            "references": [
                {
                    "tags": [
                        "government-resource"
                    ],
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-121-01"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Delta Electronics recommends users update to </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://downloadcenter.deltaww.com/en-US/DownloadCenter?v=1&amp;q=CNCSoft&amp;sort_expr=cdate&amp;sort_dir=DESC\">CNCSoft-G2 v2.1.0.4</a><span style=\"background-color: rgb(255, 255, 255);\">&nbsp;or later.</span>\n\n<br>"
                        }
                    ],
                    "value": "\nDelta Electronics recommends users update to  CNCSoft-G2 v2.1.0.4 https://downloadcenter.deltaww.com/en-US/DownloadCenter  or later.\n\n"
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "title": "Stack-based Buffer Overflow vulnerability in Delta Electronics CNCSoft-G2 DOPSoft",
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-01T20:33:52.537Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "government-resource",
                            "x_transferred"
                        ],
                        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-121-01"
                    }
                ]
            },
            {
                "affected": [
                    {
                        "vendor": "delta_electronics",
                        "product": "cncsoft-g2",
                        "cpes": [
                            "cpe:2.3:a:delta_electronics:cncsoft-g2:*:*:*:*:*:*:*:*"
                        ],
                        "defaultStatus": "unknown",
                        "versions": [
                            {
                                "version": "0",
                                "status": "affected",
                                "lessThanOrEqual": "2.0.0.5",
                                "versionType": "custom"
                            }
                        ]
                    }
                ],
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2024-08-07T13:35:46.576164Z",
                                "id": "CVE-2024-4192",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-09-03T18:16:25.046Z"
                }
            }
        ]
    }
}