    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2024-43781",
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "state": "PUBLISHED",
        "assignerShortName": "siemens",
        "dateReserved": "2024-08-16T10:13:58.486Z",
        "datePublished": "2024-09-10T09:36:51.143Z",
        "dateUpdated": "2024-09-10T14:38:36.778Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
                "shortName": "siemens",
                "dateUpdated": "2024-09-10T09:36:51.143Z"
            },
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions."
                }
            ],
            "affected": [
                {
                    "vendor": "Siemens",
                    "product": "SINUMERIK 828D V4",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V4.95 SP3",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SINUMERIK 840D sl V4",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V4.95 SP3",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SINUMERIK ONE",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V6.23",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SINUMERIK ONE",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V6.15 SP4",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
                        "baseScore": 5.5,
                        "baseSeverity": "MEDIUM"
                    }
                },
                {
                    "cvssV4_0": {
                        "version": "4.0",
                        "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                        "baseScore": 6.8,
                        "baseSeverity": "MEDIUM"
                    }
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-532",
                            "description": "CWE-532: Insertion of Sensitive Information into Log File",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://cert-portal.siemens.com/productcert/html/ssa-097786.html"
                }
            ]
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2024-09-10T14:38:29.713747Z",
                                "id": "CVE-2024-43781",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-09-10T14:38:36.778Z"
                }
            }
        ]
    }
}