    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2024-3640",
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "state": "PUBLISHED",
        "assignerShortName": "Rockwell",
        "dateReserved": "2024-04-10T20:45:50.623Z",
        "datePublished": "2024-05-16T15:25:28.558Z",
        "dateUpdated": "2024-08-01T20:20:00.578Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "FactoryTalk® Remote Access™",
                    "vendor": "Rockwell Automation",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "v13.5.0.174"
                        }
                    ]
                }
            ],
            "datePublic": "2024-05-16T15:14:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">An unquoted executable path exists in the Rockwell Automation&nbsp;FactoryTalk® Remote Access™ possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability. </span>\n\n"
                        }
                    ],
                    "value": "An unquoted executable path exists in the Rockwell Automation FactoryTalk® Remote Access™ possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability."
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-38",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-38 Leveraging/Manipulating Configuration File Search Paths"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "attackVector": "LOCAL",
                        "baseScore": 7,
                        "baseSeverity": "HIGH",
                        "privilegesRequired": "HIGH",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "subIntegrityImpact": "NONE",
                        "userInteraction": "ACTIVE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "HIGH",
                        "vulnConfidentialityImpact": "HIGH",
                        "vulnIntegrityImpact": "HIGH",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-428",
                            "description": "CWE-428 Unquoted Search Path or Element",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
                "shortName": "Rockwell",
                "dateUpdated": "2024-05-16T15:25:28.558Z"
            },
            "references": [
                {
                    "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<ul><li>Corrected in v13.6.</li></ul>"
                        }
                    ],
                    "value": "*  Corrected in v13.6."
                },
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<p>Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices below, where possible. </p><ul><li><p><a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">Security Best Practices</a>&nbsp;</p></li></ul>"
                        }
                    ],
                    "value": "Users using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply security best practices below, where possible. \n\n  *   Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
                }
            ],
            "source": {
                "discovery": "INTERNAL"
            },
            "title": "Rockwell Automation FactoryTalk® Remote Access™ has Unquoted Executables",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "title": "CISA ADP Vulnrichment",
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "id": "CVE-2024-3640",
                                "role": "CISA Coordinator",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "total"
                                    }
                                ],
                                "version": "2.0.3",
                                "timestamp": "2024-05-16T17:57:33.825467Z"
                            }
                        }
                    }
                ],
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-06-04T17:31:28.680Z"
                }
            },
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-01T20:20:00.578Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}