    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2024-30401",
        "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "state": "PUBLISHED",
        "assignerShortName": "juniper",
        "dateReserved": "2024-03-26T23:06:19.980Z",
        "datePublished": "2024-04-12T15:26:58.419Z",
        "dateUpdated": "2024-08-02T01:32:07.287Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "platforms": [
                        "MX Series",
                        "EX9200-15C"
                    ],
                    "product": "Junos OS",
                    "vendor": "Juniper Networks",
                    "versions": [
                        {
                            "lessThan": "21.2R3-S1",
                            "status": "affected",
                            "version": "21.2",
                            "versionType": "semver"
                        },
                        {
                            "lessThan": "21.4R3",
                            "status": "affected",
                            "version": "21.4",
                            "versionType": "semver"
                        },
                        {
                            "lessThan": "22.1R2",
                            "status": "affected",
                            "version": "22.1",
                            "versionType": "semver"
                        },
                        {
                            "lessThan": "22.2R2",
                            "status": "affected",
                            "version": "22.2",
                            "versionType": "semver"
                        },
                        {
                            "lessThan": "20.3R1",
                            "status": "unaffected",
                            "version": "0",
                            "versionType": "semver"
                        },
                        {
                            "status": "unaffected",
                            "version": "20.4"
                        }
                    ]
                }
            ],
            "datePublic": "2024-04-10T16:00:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "An Out-of-bounds Read vulnerability in the advanced forwarding management process aftman of Juniper Networks Junos OS on MX Series with MPC10E, MPC11, MX10K-LC9600 line cards, MX304, and EX9200-15C, may allow an attacker to exploit a stack-based buffer overflow, leading to a reboot of the FPC.<br><br>Through code review, it was determined that the interface definition code for aftman could read beyond a buffer boundary, leading to a stack-based buffer overflow.<br><p>This issue affects Junos OS on MX Series and EX9200-15C:<br></p><ul><li>from 21.2 before 21.2R3-S1, </li><li>from 21.4 before 21.4R3, </li><li>from 22.1 before 22.1R2, </li><li>from 22.2 before 22.2R2;&nbsp;</li></ul><p></p><p><span style=\"background-color: var(--darkreader-bg--wht);\">This issue does not affect:</span></p><p></p><ul><li><span style=\"background-color: var(--darkreader-bg--wht);\">versions of Junos OS prior to&nbsp;20.3R1;</span></li><li><span style=\"background-color: var(--darkreader-bg--wht);\">any version of Junos OS 20.4.</span></li></ul>"
                        }
                    ],
                    "value": "An Out-of-bounds Read vulnerability in the advanced forwarding management process aftman of Juniper Networks Junos OS on MX Series with MPC10E, MPC11, MX10K-LC9600 line cards, MX304, and EX9200-15C, may allow an attacker to exploit a stack-based buffer overflow, leading to a reboot of the FPC.\n\nThrough code review, it was determined that the interface definition code for aftman could read beyond a buffer boundary, leading to a stack-based buffer overflow.\nThis issue affects Junos OS on MX Series and EX9200-15C:\n\n\n  *  from 21.2 before 21.2R3-S1, \n  *  from 21.4 before 21.4R3, \n  *  from 22.1 before 22.1R2, \n  *  from 22.2 before 22.2R2; \n\n\n\n\nThis issue does not affect:\n\n\n\n  *  versions of Junos OS prior to 20.3R1;\n  *  any version of Junos OS 20.4."
                }
            ],
            "exploits": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
                        }
                    ],
                    "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "HIGH",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 5.9,
                        "baseSeverity": "MEDIUM",
                        "confidentialityImpact": "NONE",
                        "integrityImpact": "NONE",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                },
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "PRESENT",
                        "attackVector": "NETWORK",
                        "baseScore": 8.2,
                        "baseSeverity": "HIGH",
                        "privilegesRequired": "NONE",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "subIntegrityImpact": "NONE",
                        "userInteraction": "NONE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "HIGH",
                        "vulnConfidentialityImpact": "NONE",
                        "vulnIntegrityImpact": "NONE",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-125",
                            "description": "CWE-125 Out-of-bounds Read",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                },
                {
                    "descriptions": [
                        {
                            "description": "Denial of Service (DoS)",
                            "lang": "en"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
                "shortName": "juniper",
                "dateUpdated": "2024-05-16T18:00:45.272Z"
            },
            "references": [
                {
                    "tags": [
                        "vendor-advisory"
                    ],
                    "url": "https://supportportal.juniper.net/JSA79110"
                },
                {
                    "tags": [
                        "technical-description"
                    ],
                    "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "The following software releases have been updated to resolve this specific issue:<br><br>Junos OS: 21.2R3-S1, 21.4R3, 22.1R2, 22.2R2, 22.3R1, and all subsequent releases.<br><br>"
                        }
                    ],
                    "value": "The following software releases have been updated to resolve this specific issue:\n\nJunos OS: 21.2R3-S1, 21.4R3, 22.1R2, 22.2R2, 22.3R1, and all subsequent releases."
                }
            ],
            "source": {
                "advisory": "JSA79110",
                "defect": [
                    "1670609"
                ],
                "discovery": "INTERNAL"
            },
            "title": "Junos OS: MX Series and EX9200-15C: Stack-based buffer overflow in aftman",
            "workarounds": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<p>There are no known workarounds for this issue.</p>"
                        }
                    ],
                    "value": "There are no known workarounds for this issue."
                }
            ],
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "title": "CISA ADP Vulnrichment",
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "id": "CVE-2024-30401",
                                "role": "CISA Coordinator",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "version": "2.0.3",
                                "timestamp": "2024-04-12T17:33:00.644134Z"
                            }
                        }
                    }
                ],
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-06-04T17:38:24.398Z"
                }
            },
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T01:32:07.287Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "vendor-advisory",
                            "x_transferred"
                        ],
                        "url": "https://supportportal.juniper.net/JSA79110"
                    },
                    {
                        "tags": [
                            "technical-description",
                            "x_transferred"
                        ],
                        "url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
                    }
                ]
            }
        ]
    }
}