{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-7009",
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "state": "PUBLISHED",
        "assignerShortName": "certcc",
        "dateReserved": "2023-12-20T15:34:13.342Z",
        "datePublished": "2024-03-15T17:07:48.318Z",
        "dateUpdated": "2024-08-26T15:11:10.151Z"
    },
    "containers": {
        "cna": {
            "title": "CVE-2023-7009",
            "descriptions": [
                {
                    "lang": "en",
                    "value": "Some Sciener-based locks support plaintext message processing over Bluetooth Low Energy, allowing unencrypted malicious commands to be passed to the lock. These malicious commands, less then 16 bytes in length, will be processed by the lock as if they were encrypted communications. This can be further exploited by an attacker to compromise the lock's integrity."
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "affected": [
                {
                    "vendor": "Sciener",
                    "product": "Kontrol Lux",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "6.5.x",
                            "lessThanOrEqual": "6.5.07",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "description": "CWE-311 Missing Encryption of Sensitive Data"
                        }
                    ]
                },
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "description": "CWE-319 Cleartext Transmission of Sensitive Information"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/"
                }
            ],
            "x_generator": {
                "engine": "VINCE 2.1.11",
                "env": "prod",
                "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-7009"
            },
            "providerMetadata": {
                "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
                "shortName": "certcc",
                "dateUpdated": "2024-03-15T17:07:48.318Z"
            }
        },
        "adp": [
            {
                "affected": [
                    {
                        "vendor": "sciener",
                        "product": "kontrol_lux_firmware",
                        "cpes": [
                            "cpe:2.3:a:sciener:kontrol_lux_firmware:6.5:*:*:*:*:*:*:*"
                        ],
                        "defaultStatus": "unknown",
                        "versions": [
                            {
                                "version": "6.5",
                                "status": "affected",
                                "lessThanOrEqual": "6.5.07",
                                "versionType": "custom"
                            }
                        ]
                    }
                ],
                "metrics": [
                    {
                        "cvssV3_1": {
                            "scope": "UNCHANGED",
                            "version": "3.1",
                            "baseScore": 8.2,
                            "attackVector": "NETWORK",
                            "baseSeverity": "HIGH",
                            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
                            "integrityImpact": "HIGH",
                            "userInteraction": "NONE",
                            "attackComplexity": "LOW",
                            "availabilityImpact": "NONE",
                            "privilegesRequired": "NONE",
                            "confidentialityImpact": "LOW"
                        }
                    },
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2024-08-26T15:09:45.609770Z",
                                "id": "CVE-2023-7009",
                                "options": [
                                    {
                                        "Exploitation": "poc"
                                    },
                                    {
                                        "Automatable": "yes"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-08-26T15:11:10.151Z"
                }
            },
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T08:50:07.596Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}