    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-50821",
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "state": "PUBLISHED",
        "assignerShortName": "siemens",
        "dateReserved": "2023-12-14T15:44:45.770Z",
        "datePublished": "2024-04-09T08:34:35.452Z",
        "dateUpdated": "2024-08-12T13:49:31.775Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
                "shortName": "siemens",
                "dateUpdated": "2024-07-09T12:04:36.172Z"
            },
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition."
                }
            ],
            "affected": [
                {
                    "vendor": "Siemens",
                    "product": "SIMATIC PCS 7 V9.1",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V9.1 SP2 UC04",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SIMATIC WinCC Runtime Professional V17",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "All versions"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SIMATIC WinCC Runtime Professional V18",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V18 Update 4",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SIMATIC WinCC Runtime Professional V19",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V19 Update 1",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SIMATIC WinCC V7.5",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V7.5 SP2 Update 16",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "SIMATIC WinCC V8.0",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "0",
                            "lessThan": "V8.0 Update 5",
                            "versionType": "custom"
                        }
                    ],
                    "defaultStatus": "unknown"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                        "baseScore": 6.2,
                        "baseSeverity": "MEDIUM"
                    }
                },
                {
                    "cvssV4_0": {
                        "version": "4.0",
                        "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                        "baseScore": 6.9,
                        "baseSeverity": "MEDIUM"
                    }
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-120",
                            "description": "CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://cert-portal.siemens.com/productcert/html/ssa-730482.html"
                }
            ]
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T22:23:44.213Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://cert-portal.siemens.com/productcert/html/ssa-730482.html",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            },
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2024-08-12T13:48:36.486525Z",
                                "id": "CVE-2023-50821",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-08-12T13:49:31.775Z"
                }
            }
        ]
    }
}