    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-40223",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2023-08-21T22:12:52.593Z",
        "datePublished": "2024-07-18T16:23:18.410Z",
        "dateUpdated": "2024-08-02T18:24:55.817Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "Vue PACS",
                    "vendor": "Philips",
                    "versions": [
                        {
                            "lessThan": "12.2.8.410",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "value": "TAS Health NZ and Camiel van Es reported these vulnerabilities to Philips."
                }
            ],
            "datePublic": "2024-07-18T15:00:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "<span style=\"background-color: rgb(255, 255, 255);\">Philips Vue PACS does not properly assign, modify, track, or check actor privileges, creating an unintended sphere of control for that actor.</span>"
                        }
                    ],
                    "value": "Philips Vue PACS does not properly assign, modify, track, or check actor privileges, creating an unintended sphere of control for that actor."
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "NONE",
                        "baseScore": 4.4,
                        "baseSeverity": "MEDIUM",
                        "confidentialityImpact": "LOW",
                        "integrityImpact": "LOW",
                        "privilegesRequired": "LOW",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                },
                {
                    "cvssV4_0": {
                        "Automatable": "NOT_DEFINED",
                        "Recovery": "NOT_DEFINED",
                        "Safety": "NOT_DEFINED",
                        "attackComplexity": "LOW",
                        "attackRequirements": "NONE",
                        "attackVector": "LOCAL",
                        "baseScore": 4.8,
                        "baseSeverity": "MEDIUM",
                        "privilegesRequired": "LOW",
                        "providerUrgency": "NOT_DEFINED",
                        "subAvailabilityImpact": "NONE",
                        "subConfidentialityImpact": "NONE",
                        "subIntegrityImpact": "NONE",
                        "userInteraction": "NONE",
                        "valueDensity": "NOT_DEFINED",
                        "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
                        "version": "4.0",
                        "vulnAvailabilityImpact": "NONE",
                        "vulnConfidentialityImpact": "LOW",
                        "vulnIntegrityImpact": "LOW",
                        "vulnerabilityResponseEffort": "NOT_DEFINED"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-269",
                            "description": "CWE-269 Improper Privilege Management",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2024-07-18T16:23:18.410Z"
            },
            "references": [
                {
                    "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01"
                },
                {
                    "url": "http://www.philips.com/productsecurity"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "Philips recommends upgrading to the latest Vue PACS version 12.2.8.400* released in August 2023.<br><p>For managed services customers, new releases will be made available upon resource availability. Releases are subject to country specific regulations. Users with questions regarding their specific Philips Vue PACS installations and new release eligibility should contact their local Philips Sales representative or submit a request in the <a target=\"_blank\" rel=\"nofollow\" href=\"https://usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/www.informatics.support.philips.com/csm\">Philips Informatics Support portal</a>.</p><p>Refer to the <a target=\"_blank\" rel=\"nofollow\" href=\"http://www.philips.com/productsecurity\">Philips advisory</a>&nbsp;for more details.</p>\n\n<br>"
                        }
                    ],
                    "value": "Philips recommends upgrading to the latest Vue PACS version 12.2.8.400* released in August 2023.\nFor managed services customers, new releases will be made available upon resource availability. Releases are subject to country specific regulations. Users with questions regarding their specific Philips Vue PACS installations and new release eligibility should contact their local Philips Sales representative or submit a request in the  Philips Informatics Support portal https://usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/www.informatics.support.philips.com/csm .\n\nRefer to the  Philips advisory http://www.philips.com/productsecurity  for more details."
                }
            ],
            "source": {
                "advisory": "ICSMA-24-200-01",
                "discovery": "EXTERNAL"
            },
            "title": "Philips Vue PACS Improper Privilege Management",
            "x_generator": {
                "engine": "Vulnogram 0.2.0"
            }
        },
        "adp": [
            {
                "metrics": [
                    {
                        "other": {
                            "type": "ssvc",
                            "content": {
                                "timestamp": "2024-07-18T18:41:38.401431Z",
                                "id": "CVE-2023-40223",
                                "options": [
                                    {
                                        "Exploitation": "none"
                                    },
                                    {
                                        "Automatable": "no"
                                    },
                                    {
                                        "Technical Impact": "partial"
                                    }
                                ],
                                "role": "CISA Coordinator",
                                "version": "2.0.3"
                            }
                        }
                    }
                ],
                "title": "CISA ADP Vulnrichment",
                "providerMetadata": {
                    "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
                    "shortName": "CISA-ADP",
                    "dateUpdated": "2024-07-18T18:41:52.633Z"
                }
            },
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T18:24:55.817Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-200-01",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "http://www.philips.com/productsecurity",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}