    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-3256",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2023-06-14T22:19:56.799Z",
        "datePublished": "2023-06-22T16:21:25.727Z",
        "dateUpdated": "2024-08-02T06:48:08.257Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "R-SeeNet",
                    "vendor": "Advantech ",
                    "versions": [
                        {
                            "lessThanOrEqual": "2.4.22",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "user": "00000000-0000-4000-9000-000000000000",
                    "value": "Esjay, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to CISA."
                }
            ],
            "datePublic": "2023-06-22T16:18:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\nAdvantech R-SeeNet \nversions 2.4.22 \nallows low-level users to access and load the content of local files.\n\n\n\n"
                        }
                    ],
                    "value": "Advantech R-SeeNet \nversions 2.4.22 \nallows low-level users to access and load the content of local files.\n\n\n\n"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 8.8,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "LOW",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-73",
                            "description": "CWE-73 External Control of File Name or Path",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2023-06-22T16:21:25.727Z"
            },
            "references": [
                {
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-02"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\nAdvantech released R-SeeNet 2.4.23, which fixes both vulnerabilities. All users are recommended to upgrade to this version: <a target=\"_blank\" rel=\"nofollow\" href=\"https://icr.advantech.cz/products/software/r-seenet\">https://icr.advantech.cz/products/software/r-seenet</a>\n\n<br>"
                        }
                    ],
                    "value": "Advantech released R-SeeNet 2.4.23, which fixes both vulnerabilities. All users are recommended to upgrade to this version:  https://icr.advantech.cz/products/software/r-seenet https://icr.advantech.cz/products/software/r-seenet \n\n\n"
                }
            ],
            "source": {
                "discovery": "EXTERNAL"
            },
            "title": "Advantech R-SeeNet External Control of File Name or Path",
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T06:48:08.257Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-173-02",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}