    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-31222",
        "assignerOrgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
        "state": "PUBLISHED",
        "assignerShortName": "Medtronic",
        "dateReserved": "2023-04-25T17:42:44.778Z",
        "datePublished": "2023-06-29T15:19:22.621Z",
        "dateUpdated": "2024-08-02T14:53:30.992Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "platforms": [
                        "Windows"
                    ],
                    "product": "Paceart Optima ",
                    "vendor": "Medtronic",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "Versions 1.11 and earlier"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "user": "00000000-0000-4000-9000-000000000000",
                    "value": "Medtronic"
                }
            ],
            "datePublic": "2023-06-29T15:05:00.000Z",
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "Deserialization of untrusted data&nbsp;in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a<span style=\"background-color: rgb(255, 255, 255);\">&nbsp;healthcare delivery organization’s Paceart Optima system&nbsp;cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration</span>&nbsp;via network connectivity."
                        }
                    ],
                    "value": "Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity."
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 9.8,
                        "baseSeverity": "CRITICAL",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-502",
                            "description": "CWE-502",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "3c337f33-b2bd-4529-9792-f48cdb2838b4",
                "shortName": "Medtronic",
                "dateUpdated": "2023-06-29T15:24:24.829Z"
            },
            "references": [
                {
                    "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "Refer to Medtronic Security Bulletin:&nbsp;<a target=\"_blank\" rel=\"nofollow\" href=\"https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html\">https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html</a>"
                        }
                    ],
                    "value": "Refer to Medtronic Security Bulletin:  https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html "
                }
            ],
            "source": {
                "discovery": "INTERNAL"
            },
            "title": "Medtronic Paceart MSMQ Deserialization of Untrusted Data",
            "workarounds": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\nRefer to Medtronic Security Bulletin: <a target=\"_blank\" rel=\"nofollow\" href=\"https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html\">https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html</a>\n\n<br>"
                        }
                    ],
                    "value": "\nRefer to Medtronic Security Bulletin:  https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html \n\n\n"
                }
            ],
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T14:53:30.992Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}