    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-28895",
        "assignerOrgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
        "state": "PUBLISHED",
        "assignerShortName": "ASRG",
        "dateReserved": "2023-03-27T14:51:13.967Z",
        "datePublished": "2023-12-01T13:41:16.581Z",
        "dateUpdated": "2024-08-02T13:51:38.834Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "MIB3 Infotainment Unit",
                    "vendor": "JOYNEXT",
                    "versions": [
                        {
                            "lessThanOrEqual": "0304",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "user": "00000000-0000-4000-9000-000000000000",
                    "value": "Danila Parnishchev (PCAutomotive)"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "The password for access to the debugging console of the PoWer Controller chip (PWC) of the MIB3 infotainment is hard-coded in the firmware. The console allows attackers with physical access to the MIB3 unit to gain full control over the PWC chip.<br><br>Vulnerability found on&nbsp;<span style=\"background-color: var(--wht);\">Škoda Superb III (3V3) - 2.0 TDI manufactured in 2022.</span>"
                        }
                    ],
                    "value": "The password for access to the debugging console of the PoWer Controller chip (PWC) of the MIB3 infotainment is hard-coded in the firmware. The console allows attackers with physical access to the MIB3 unit to gain full control over the PWC chip.\n\nVulnerability found on Škoda Superb III (3V3) - 2.0 TDI manufactured in 2022."
                }
            ],
            "impacts": [
                {
                    "capecId": "CAPEC-37",
                    "descriptions": [
                        {
                            "lang": "en",
                            "value": "CAPEC-37: Retrieve Embedded Sensitive Data"
                        }
                    ]
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "PHYSICAL",
                        "availabilityImpact": "LOW",
                        "baseScore": 3.5,
                        "baseSeverity": "LOW",
                        "confidentialityImpact": "NONE",
                        "integrityImpact": "LOW",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-259",
                            "description": "CWE-259",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
                "shortName": "ASRG",
                "dateUpdated": "2024-04-24T14:25:01.361Z"
            },
            "references": [
                {
                    "url": "https://asrg.io/security-advisories/hard-coded-password-for-access-to-power-controller-chip-memory/"
                }
            ],
            "source": {
                "discovery": "EXTERNAL"
            },
            "title": "Hard-coded password for access to power controller chip memory",
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T13:51:38.834Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://asrg.io/security-advisories/hard-coded-password-for-access-to-power-controller-chip-memory/",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}