{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-1709",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2023-03-29T22:59:38.901Z",
        "datePublished": "2023-06-07T20:36:05.055Z",
        "dateUpdated": "2024-08-02T05:57:25.034Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "JT2Go",
                    "vendor": "Siemens ",
                    "versions": [
                        {
                            "lessThan": "14.2.0.2",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "Teamcenter Visualization",
                    "vendor": "Siemens ",
                    "versions": [
                        {
                            "lessThan": "13.2.0.13",
                            "status": "affected",
                            "version": "13.2",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "13.3.0.9",
                            "status": "affected",
                            "version": "13.3",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "14.0.0.5",
                            "status": "affected",
                            "version": "14.0",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "14.1.0.7",
                            "status": "affected",
                            "version": "14.1",
                            "versionType": "custom"
                        },
                        {
                            "lessThan": "14.2.0.2",
                            "status": "affected",
                            "version": "14.2",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "Library APDFL",
                    "vendor": "Datalogics",
                    "versions": [
                        {
                            "lessThanOrEqual": "v18.0.4PlusP1e",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "user": "00000000-0000-4000-9000-000000000000",
                    "value": "Michael Heinzl reported this vulnerability to Siemens. "
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\nDatalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.\n\n \n\n"
                        }
                    ],
                    "value": "\nDatalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.\n\n \n\n"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 7.8,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "REQUIRED",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                },
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 5.5,
                        "baseSeverity": "MEDIUM",
                        "confidentialityImpact": "NONE",
                        "integrityImpact": "NONE",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "REQUIRED",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-121",
                            "description": "CWE-121: Stack-based Buffer Overflow",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2023-06-14T20:17:02.964Z"
            },
            "references": [
                {
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-11"
                },
                {
                    "url": "https://cert-portal.siemens.com/productcert/html/ssa-629917.html"
                },
                {
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-164-01"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n<div>Siemens has released updates for the affected products and recommends updating to the latest versions:</div><ul><li>JT2Go: <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\">Update to V14.2.0.2</a> or later version</li><li>Teamcenter Visualization V13.2: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.2.0.13</a>&nbsp; or later version </li><li>Teamcenter Visualization V13.3: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.3.0.9</a>&nbsp; or later version </li><li>Teamcenter Visualization V14.0: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.0.0.5</a>&nbsp; or later version </li><li>Teamcenter Visualization V14.1: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.1.0.7</a>&nbsp; or later version </li><li>Teamcenter Visualization V14.2: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.2.0.2</a>&nbsp; or later version \n\n</li></ul>"
                        }
                    ],
                    "value": "Siemens has released updates for the affected products and recommends updating to the latest versions:\n\n  *  JT2Go:  Update to V14.2.0.2 https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html  or later version\n  *  Teamcenter Visualization V13.2:  Update to V13.2.0.13 https://support.sw.siemens.com/   or later version \n  *  Teamcenter Visualization V13.3:  Update to V13.3.0.9 https://support.sw.siemens.com/   or later version \n  *  Teamcenter Visualization V14.0:  Update to V14.0.0.5 https://support.sw.siemens.com/   or later version \n  *  Teamcenter Visualization V14.1:  Update to V14.1.0.7 https://support.sw.siemens.com/   or later version \n  *  Teamcenter Visualization V14.2:  Update to V14.2.0.2 https://support.sw.siemens.com/   or later version \n\n\n\n\n"
                }
            ],
            "source": {
                "discovery": "EXTERNAL"
            },
            "title": "Datalogics Library APDFL Stack-based Buffer Overflow",
            "workarounds": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n<p>Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risks: </p>\n<ul><li>Avoid opening untrusted files in JT2Go and Teamcenter Visualization </li>\n</ul><p>As a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens' <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">operational guidelines for industrial security</a>,\n and to follow the recommendations in the product manuals. Additional \ninformation on industrial security by Siemens can be found at the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\">Siemens Industrial Security web page</a>. \n</p><p>For further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\">Siemens ProductCERT</a>.</p>"
                        }
                    ],
                    "value": "Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risks: \n\n\n  *  Avoid opening untrusted files in JT2Go and Teamcenter Visualization \n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens'  operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security ,\n and to follow the recommendations in the product manuals. Additional \ninformation on industrial security by Siemens can be found at the  Siemens Industrial Security web page https://www.siemens.com/industrialsecurity . \n\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the  Siemens ProductCERT https://www.siemens.com/cert/advisories .\n\n"
                },
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n<p>Datalogics recommends users to update to APDFL v18.0.4PlusP1g. <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.datalogics.com/datalogics-contact-us\">Contact Datalogics</a>&nbsp;for more information on obtaining this update.</p><p>For more information, refer to <a target=\"_blank\" rel=\"nofollow\" href=\"https://dev.datalogics.com/adobe-pdf-library/release-notes-adobe-pdf-library-v-18/\">Datalogic’s release notes</a>.</p>\n\n<br>"
                        }
                    ],
                    "value": "Datalogics recommends users to update to APDFL v18.0.4PlusP1g.  Contact Datalogics https://www.datalogics.com/datalogics-contact-us  for more information on obtaining this update.\n\nFor more information, refer to  Datalogic’s release notes https://dev.datalogics.com/adobe-pdf-library/release-notes-adobe-pdf-library-v-18/ .\n\n\n\n\n"
                }
            ],
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T05:57:25.034Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-11",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://cert-portal.siemens.com/productcert/html/ssa-629917.html",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-164-01",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}