{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2023-1285",
        "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "state": "PUBLISHED",
        "assignerShortName": "Mitsubishi",
        "dateReserved": "2023-03-09T08:05:46.845Z",
        "datePublished": "2023-04-14T02:17:55.175Z",
        "dateUpdated": "2024-08-02T05:41:00.062Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "GC-ENET-COM",
                    "vendor": "Mitsubishi Electric India",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "SN:16XXXXXXXXX"
                        }
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are \"16\" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.<br>"
                        }
                    ],
                    "value": "Signal Handler Race Condition vulnerability in Mitsubishi Electric India GC-ENET-COM whose first 2 digits of 11-digit serial number of unit are \"16\" allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in Ethernet communication by sending a large number of specially crafted packets to any UDP port when GC-ENET-COM is configured as a Modbus TCP Server. The communication resumes only when the power of the main unit is turned off and on or when the GC-ENET-COM is hot-swapped from the main unit.\n"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 7.5,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "NONE",
                        "integrityImpact": "NONE",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-364",
                            "description": "CWE-364 Signal Handler Race Condition",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
                "shortName": "Mitsubishi",
                "dateUpdated": "2023-04-14T02:17:55.175Z"
            },
            "references": [
                {
                    "tags": [
                        "vendor-advisory"
                    ],
                    "url": "https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf"
                },
                {
                    "tags": [
                        "government-resource"
                    ],
                    "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15"
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-02T05:41:00.062Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "vendor-advisory",
                            "x_transferred"
                        ],
                        "url": "https://mitsubishielectric.in/fa/cnc-pdf/DoS_in_Ethernet_Communication_Extension_Unit_GC_ENET_COM_of_GOC35_Series.pdf"
                    },
                    {
                        "tags": [
                            "government-resource",
                            "x_transferred"
                        ],
                        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-15"
                    }
                ]
            }
        ]
    }
}