    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "state": "PUBLISHED",
        "cveId": "CVE-2022-43397",
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "dateUpdated": "2024-08-03T13:32:57.387Z",
        "dateReserved": "2022-10-18T00:00:00",
        "datePublished": "2022-11-08T00:00:00"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
                "shortName": "siemens",
                "dateUpdated": "2023-02-15T09:24:50.974Z"
            },
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)"
                }
            ],
            "affected": [
                {
                    "vendor": "Siemens",
                    "product": "Parasolid V34.0",
                    "versions": [
                        {
                            "version": "All versions < V34.0.252",
                            "status": "affected"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "Parasolid V34.1",
                    "versions": [
                        {
                            "version": "All versions < V34.1.242",
                            "status": "affected"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "Parasolid V35.0",
                    "versions": [
                        {
                            "version": "All versions < V35.0.170",
                            "status": "affected"
                        }
                    ],
                    "defaultStatus": "unknown"
                },
                {
                    "vendor": "Siemens",
                    "product": "Simcenter Femap",
                    "versions": [
                        {
                            "version": "All versions < V2023.1",
                            "status": "affected"
                        }
                    ],
                    "defaultStatus": "unknown"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                        "baseScore": 7.8,
                        "baseSeverity": "HIGH"
                    }
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-787",
                            "description": "CWE-787: Out-of-bounds Write",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
                },
                {
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
                }
            ]
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-03T13:32:57.387Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}