    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2022-41613",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2022-09-29T14:08:03.169Z",
        "datePublished": "2023-01-06T21:11:43.209Z",
        "dateUpdated": "2024-08-03T12:49:43.409Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "MicroStation Connect",
                    "vendor": "Bentley Systems",
                    "versions": [
                        {
                            "lessThanOrEqual": "10.17.0.209",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "user": "00000000-0000-4000-9000-000000000000",
                    "value": "Michael Heinzl"
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<span style=\"background-color: rgb(255, 255, 255);\">Bentley Systems MicroStation Connect</span>&nbsp;versions \n\n10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when<span style=\"background-color: rgb(255, 255, 255);\">&nbsp;<span style=\"background-color: rgb(255, 255, 255);\">when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code.</span>\n\n</span>"
                        }
                    ],
                    "value": "\nBentley Systems MicroStation Connect versions \n\n10.17.0.209 and prior are vulnerable to an Out-of-Bounds Read when when parsing DGN files, which may allow an attacker to crash the product, disclose sensitive information, or execute arbitrary code.\n\n"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 7.8,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "REQUIRED",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-125",
                            "description": "CWE-125 Out-of-bounds Read",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2023-01-06T21:11:43.209Z"
            },
            "references": [
                {
                    "tags": [
                        "government-resource"
                    ],
                    "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
                },
                {
                    "url": "https://www.bentley.com/advisories/be-2023-0003/"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n\n<p>Bentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:</p><ul><li>MicroStation Connect Update 17.1</li></ul><p>For more information and MicroStation updates, contact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.bentley.com/support/\">Bentley Support</a>.</p>\n\n<br>"
                        }
                    ],
                    "value": "\nBentley Systems has implemented multiple validation checks within the DGN platform when processing malformed DGNs. Bentley Systems recommends users update to the latest version of the MicroStation Connect:\n\n  *  MicroStation Connect Update 17.1\n\n\nFor more information and MicroStation updates, contact  Bentley Support https://www.bentley.com/support/ .\n\n\n\n\n"
                }
            ],
            "source": {
                "discovery": "UNKNOWN"
            },
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-03T12:49:43.409Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "government-resource",
                            "x_transferred"
                        ],
                        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-293-01"
                    },
                    {
                        "url": "https://www.bentley.com/advisories/be-2023-0003/",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}