{
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "state": "PUBLISHED",
        "cveId": "CVE-2022-3228",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "datePublished": "2022-10-28T17:17:46.811087Z",
        "dateUpdated": "2024-09-16T17:15:20.303Z",
        "dateReserved": "2022-09-15T00:00:00"
    },
    "containers": {
        "cna": {
            "datePublic": "2022-09-20T00:00:00",
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2022-10-28T00:00:00"
            },
            "descriptions": [
                {
                    "lang": "en",
                    "value": "Using custom code, an attacker can write into name or description fields larger than the appropriate buffer size causing a stack-based buffer overflow on Host Engineering H0-ECOM100 Communications Module Firmware versions v5.0.155 and prior. This may allow an attacker to crash the affected device or cause it to become unresponsive."
                }
            ],
            "affected": [
                {
                    "vendor": "Host Engineering",
                    "product": "H0-ECOM100 Communications Module",
                    "versions": [
                        {
                            "version": "All versions",
                            "status": "affected",
                            "lessThanOrEqual": "Firmware v5.0.155",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-263-04"
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "David Formby and Caleb Purcell of Fortiphyd Logic reported this vulnerability."
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                        "attackVector": "ADJACENT_NETWORK",
                        "attackComplexity": "LOW",
                        "privilegesRequired": "NONE",
                        "userInteraction": "NONE",
                        "scope": "UNCHANGED",
                        "confidentialityImpact": "NONE",
                        "integrityImpact": "NONE",
                        "availabilityImpact": "HIGH",
                        "baseScore": 6.5,
                        "baseSeverity": "MEDIUM"
                    }
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "type": "CWE",
                            "lang": "en",
                            "description": "CWE-121 Stack-based Buffer Overflow",
                            "cweId": "CWE-121"
                        }
                    ]
                }
            ],
            "x_generator": {
                "engine": "Vulnogram 0.0.9"
            },
            "source": {
                "discovery": "UNKNOWN"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-03T01:00:10.822Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-263-04",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}