    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2022-3159",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "state": "PUBLISHED",
        "assignerShortName": "icscert",
        "dateReserved": "2022-09-07T23:36:59.702Z",
        "datePublished": "2023-01-13T00:15:15.775Z",
        "dateUpdated": "2024-08-03T01:00:10.535Z"
    },
    "containers": {
        "cna": {
            "affected": [
                {
                    "defaultStatus": "unaffected",
                    "product": "JT2Go",
                    "vendor": "Siemens ",
                    "versions": [
                        {
                            "lessThan": "14.1.0.5",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "Teamcenter Visualization V13.3",
                    "vendor": "Siemens ",
                    "versions": [
                        {
                            "lessThan": "13.3.0.8",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "Teamcenter Visualization V14.0",
                    "vendor": "Siemens ",
                    "versions": [
                        {
                            "lessThan": "14.0.0.4",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "defaultStatus": "unaffected",
                    "product": "Teamcenter Visualization V14.1",
                    "vendor": "Siemens ",
                    "versions": [
                        {
                            "lessThan": "14.1.0.5",
                            "status": "affected",
                            "version": "0",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "type": "finder",
                    "user": "00000000-0000-4000-9000-000000000000",
                    "value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens. "
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\nThe APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n"
                        }
                    ],
                    "value": "The APDFL.dll contains a stack-based buffer overflow vulnerability that \ncould be triggered while parsing specially crafted PDF files. This could\n allow an attacker to execute code in the context of the current \nprocess.\n\n"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "attackComplexity": "LOW",
                        "attackVector": "LOCAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 7.8,
                        "baseSeverity": "HIGH",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "REQUIRED",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                        "version": "3.1"
                    },
                    "format": "CVSS",
                    "scenarios": [
                        {
                            "lang": "en",
                            "value": "GENERAL"
                        }
                    ]
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-121",
                            "description": "CWE-121 ",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2023-01-13T00:15:15.775Z"
            },
            "references": [
                {
                    "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
                },
                {
                    "url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
                },
                {
                    "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:<br><ul><li><span style=\"background-color: var(--wht);\">JT2Go: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">.&nbsp;<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V13.3: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.3.0.8 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.0: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.0.0.4 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.1: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">.</span></li></ul>"
                        }
                    ],
                    "value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n  *  JT2Go:  Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html . \n\n  *  Teamcenter Visualization V13.3:  Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n  *  Teamcenter Visualization V14.0:  Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n  *  Teamcenter Visualization V14.1:  Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
                }
            ],
            "source": {
                "discovery": "EXTERNAL"
            },
            "workarounds": [
                {
                    "lang": "en",
                    "supportingMedia": [
                        {
                            "base64": false,
                            "type": "text/html",
                            "value": "\n<p>Siemens identified the following specific workaround and mitigation user can apply to reduce risk: </p>\n\n<ul><li>Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.</li>\n</ul><p>As a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens' <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">operational guidelines for industrial security</a></p> and following the recommendations in the product manuals. Siemens also provides <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\">additional information on industrial security</a>.<br>\nFor further inquiries on security vulnerabilities in Siemens products, users should contact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\">Siemens</a>. <br>\nFor more information, see the associated Siemens security advisory SSA-360681 in <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\">HTML </a>and <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\">CSAF</a>.\n\n<br>"
                        }
                    ],
                    "value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n  *  Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens'  operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides  additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact  Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in  HTML  https://cert-portal.siemens.com/productcert/html/ssa-360681.html and  CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
                }
            ],
            "x_generator": {
                "engine": "Vulnogram 0.1.0-dev"
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-03T01:00:10.535Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}