    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "cveId": "CVE-2022-39062",
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "state": "PUBLISHED",
        "assignerShortName": "siemens",
        "dateReserved": "2022-08-31T12:35:09.544Z",
        "datePublished": "2023-08-08T09:20:11.510Z",
        "dateUpdated": "2024-08-03T11:10:32.430Z"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
                "shortName": "siemens",
                "dateUpdated": "2023-08-08T09:20:11.510Z"
            },
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A vulnerability has been identified in SICAM TOOLBOX II (All versions < V07.10). Affected applications do not properly set permissions for product folders. This could allow an authenticated attacker with low privileges to replace DLLs and conduct a privilege escalation."
                }
            ],
            "affected": [
                {
                    "vendor": "Siemens",
                    "product": "SICAM TOOLBOX II",
                    "versions": [
                        {
                            "version": "All versions < V07.10",
                            "status": "affected"
                        }
                    ],
                    "defaultStatus": "unknown"
                }
            ],
            "metrics": [
                {
                    "cvssV3_1": {
                        "version": "3.1",
                        "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                        "baseScore": 7.8,
                        "baseSeverity": "HIGH"
                    }
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "lang": "en",
                            "cweId": "CWE-732",
                            "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-975961.pdf"
                }
            ]
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-03T11:10:32.430Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-975961.pdf",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}