    "containers": {
        "cna": {
            "affected": [
                {
                    "product": "JT Utilities",
                    "vendor": "Siemens",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "All versions < V13.0.2.0"
                        }
                    ]
                }
            ],
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a hash function is called with an incorrect argument leading the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-688",
                            "description": "CWE-688: Function Call With Incorrect Variable or Reference as Argument",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "dateUpdated": "2021-07-13T11:03:03",
                "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
                "shortName": "siemens"
            },
            "references": [
                {
                    "tags": [
                        "x_refsource_MISC"
                    ],
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
                }
            ],
            "x_legacyV4Record": {
                "CVE_data_meta": {
                    "ASSIGNER": "productcert@siemens.com",
                    "ID": "CVE-2021-33713",
                    "STATE": "PUBLIC"
                },
                "affects": {
                    "vendor": {
                        "vendor_data": [
                            {
                                "product": {
                                    "product_data": [
                                        {
                                            "product_name": "JT Utilities",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "version_value": "All versions < V13.0.2.0"
                                                    }
                                                ]
                                            }
                                        }
                                    ]
                                },
                                "vendor_name": "Siemens"
                            }
                        ]
                    }
                },
                "data_format": "MITRE",
                "data_type": "CVE",
                "data_version": "4.0",
                "description": {
                    "description_data": [
                        {
                            "lang": "eng",
                            "value": "A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a hash function is called with an incorrect argument leading the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application."
                        }
                    ]
                },
                "problemtype": {
                    "problemtype_data": [
                        {
                            "description": [
                                {
                                    "lang": "eng",
                                    "value": "CWE-688: Function Call With Incorrect Variable or Reference as Argument"
                                }
                            ]
                        }
                    ]
                },
                "references": {
                    "reference_data": [
                        {
                            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf",
                            "refsource": "MISC",
                            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
                        }
                    ]
                }
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-03T23:58:22.818Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "x_refsource_MISC",
                            "x_transferred"
                        ],
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf"
                    }
                ]
            }
        ]
    },
    "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-33713",
        "datePublished": "2021-07-13T11:03:03",
        "dateReserved": "2021-05-28T00:00:00",
        "dateUpdated": "2024-08-03T23:58:22.818Z",
        "state": "PUBLISHED"
    },
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1"
}