    "dataType": "CVE_RECORD",
    "dataVersion": "5.1",
    "cveMetadata": {
        "state": "PUBLISHED",
        "cveId": "CVE-2021-32940",
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "dateUpdated": "2024-08-03T23:33:56.100Z",
        "dateReserved": "2021-05-13T00:00:00",
        "datePublished": "2021-06-17T00:00:00"
    },
    "containers": {
        "cna": {
            "providerMetadata": {
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert",
                "dateUpdated": "2023-01-13T00:00:00"
            },
            "descriptions": [
                {
                    "lang": "en",
                    "value": "An out-of-bounds read issue exists in the DWG file-recovering procedure in the Drawings SDK (All versions prior to 2022.5) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations."
                }
            ],
            "affected": [
                {
                    "vendor": "n/a",
                    "product": "Drawings SDK",
                    "versions": [
                        {
                            "version": "All versions prior to 2022.4",
                            "status": "affected"
                        }
                    ]
                }
            ],
            "references": [
                {
                    "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"
                },
                {
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
                },
                {
                    "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/"
                },
                {
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "type": "CWE",
                            "lang": "en",
                            "description": "OUT-OF-BOUNDS READ CWE-125",
                            "cweId": "CWE-125"
                        }
                    ]
                }
            ]
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-03T23:33:56.100Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/",
                        "tags": [
                            "x_transferred"
                        ]
                    },
                    {
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf",
                        "tags": [
                            "x_transferred"
                        ]
                    }
                ]
            }
        ]
    }
}