    "containers": {
        "cna": {
            "affected": [
                {
                    "product": "KR3R540, KRC4, KSS8.5.7HF1, Win7_Embedded",
                    "vendor": "KUKA Roboter GmbH",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "unspecified"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "Alias Robotics (group, https://aliasrobotics.com)"
                }
            ],
            "datePublic": "2020-06-16T00:00:00",
            "descriptions": [
                {
                    "lang": "en",
                    "value": "Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-Calibration of the brakes needs to be performed. Be noted that this only can be accomplished either by a Kuka technician or by Kuka issued calibration hardware that interfaces with the manipulator furthering the delay and increasing operational costs."
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-749",
                            "description": "CWE-749",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "dateUpdated": "2020-06-16T17:55:11",
                "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
                "shortName": "Alias"
            },
            "references": [
                {
                    "tags": [
                        "x_refsource_CONFIRM"
                    ],
                    "url": "https://github.com/aliasrobotics/RVD/issues/2550"
                }
            ],
            "source": {
                "defect": [
                    "RVD#2550"
                ],
                "discovery": "EXTERNAL"
            },
            "title": "RVD#2550: Terminate Critical Services in KUKA controller KR C4",
            "x_ConverterErrors": {
                "cvssV3_0": {
                    "error": "CVSSV3_0 data from v4 record is invalid",
                    "message": "Malformed CVSS3 vector, trailing \"/\""
                }
            },
            "x_generator": {
                "engine": "Robot Vulnerability Database (RVD)"
            },
            "x_legacyV4Record": {
                "CVE_data_meta": {
                    "ASSIGNER": "cve@aliasrobotics.com",
                    "DATE_PUBLIC": "2020-06-16T17:49:11 +00:00",
                    "ID": "CVE-2020-10268",
                    "STATE": "PUBLIC",
                    "TITLE": "RVD#2550: Terminate Critical Services in KUKA controller KR C4"
                },
                "affects": {
                    "vendor": {
                        "vendor_data": [
                            {
                                "product": {
                                    "product_data": [
                                        {
                                            "product_name": "KR3R540, KRC4, KSS8.5.7HF1, Win7_Embedded",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "version_value": ""
                                                    }
                                                ]
                                            }
                                        }
                                    ]
                                },
                                "vendor_name": "KUKA Roboter GmbH"
                            }
                        ]
                    }
                },
                "credit": [
                    {
                        "lang": "eng",
                        "value": "Alias Robotics (group, https://aliasrobotics.com)"
                    }
                ],
                "data_format": "MITRE",
                "data_type": "CVE",
                "data_version": "4.0",
                "description": {
                    "description_data": [
                        {
                            "lang": "eng",
                            "value": "Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-Calibration of the brakes needs to be performed. Be noted that this only can be accomplished either by a Kuka technician or by Kuka issued calibration hardware that interfaces with the manipulator furthering the delay and increasing operational costs."
                        }
                    ]
                },
                "generator": {
                    "engine": "Robot Vulnerability Database (RVD)"
                },
                "impact": {
                    "cvss": {
                        "attackComplexity": "LOW",
                        "attackVector": "PHYSICAL",
                        "availabilityImpact": "HIGH",
                        "baseScore": 6.1,
                        "baseSeverity": "medium",
                        "confidentialityImpact": "LOW",
                        "integrityImpact": "NONE",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H/",
                        "version": "3.0"
                    }
                },
                "problemtype": {
                    "problemtype_data": [
                        {
                            "description": [
                                {
                                    "lang": "eng",
                                    "value": "CWE-749"
                                }
                            ]
                        }
                    ]
                },
                "references": {
                    "reference_data": [
                        {
                            "name": "https://github.com/aliasrobotics/RVD/issues/2550",
                            "refsource": "CONFIRM",
                            "url": "https://github.com/aliasrobotics/RVD/issues/2550"
                        }
                    ]
                },
                "source": {
                    "defect": [
                        "RVD#2550"
                    ],
                    "discovery": "EXTERNAL"
                }
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-04T10:58:40.108Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "x_refsource_CONFIRM",
                            "x_transferred"
                        ],
                        "url": "https://github.com/aliasrobotics/RVD/issues/2550"
                    }
                ]
            }
        ]
    },
    "cveMetadata": {
        "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
        "assignerShortName": "Alias",
        "cveId": "CVE-2020-10268",
        "datePublished": "2020-06-16T17:55:11.700406Z",
        "dateReserved": "2020-03-10T00:00:00",
        "dateUpdated": "2024-09-16T18:59:43.071Z",
        "state": "PUBLISHED"
    },
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1"
}