{
    "containers": {
        "cna": {
            "affected": [
                {
                    "product": "UltraVNC",
                    "vendor": "Kaspersky Lab",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "1.2.2.3"
                        }
                    ]
                }
            ],
            "datePublic": "2019-03-01T00:00:00",
            "descriptions": [
                {
                    "lang": "en",
                    "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208."
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-788",
                            "description": "CWE-788: Access of Memory Location After End of Buffer",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "dateUpdated": "2021-06-28T11:57:30",
                "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
                "shortName": "Kaspersky"
            },
            "references": [
                {
                    "tags": [
                        "x_refsource_MISC"
                    ],
                    "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/"
                },
                {
                    "tags": [
                        "x_refsource_CONFIRM"
                    ],
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
                },
                {
                    "tags": [
                        "x_refsource_MISC"
                    ],
                    "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
                },
                {
                    "tags": [
                        "x_refsource_CONFIRM"
                    ],
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
                },
                {
                    "tags": [
                        "x_refsource_CONFIRM"
                    ],
                    "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                },
                {
                    "tags": [
                        "x_refsource_MISC"
                    ],
                    "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
                }
            ],
            "x_legacyV4Record": {
                "CVE_data_meta": {
                    "ASSIGNER": "vulnerability@kaspersky.com",
                    "DATE_PUBLIC": "2019-03-01T00:00:00",
                    "ID": "CVE-2019-8265",
                    "STATE": "PUBLIC"
                },
                "affects": {
                    "vendor": {
                        "vendor_data": [
                            {
                                "product": {
                                    "product_data": [
                                        {
                                            "product_name": "UltraVNC",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "version_value": "1.2.2.3"
                                                    }
                                                ]
                                            }
                                        }
                                    ]
                                },
                                "vendor_name": "Kaspersky Lab"
                            }
                        ]
                    }
                },
                "data_format": "MITRE",
                "data_type": "CVE",
                "data_version": "4.0",
                "description": {
                    "description_data": [
                        {
                            "lang": "eng",
                            "value": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208."
                        }
                    ]
                },
                "problemtype": {
                    "problemtype_data": [
                        {
                            "description": [
                                {
                                    "lang": "eng",
                                    "value": "CWE-788: Access of Memory Location After End of Buffer"
                                }
                            ]
                        }
                    ]
                },
                "references": {
                    "reference_data": [
                        {
                            "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/",
                            "refsource": "MISC",
                            "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/"
                        },
                        {
                            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
                            "refsource": "CONFIRM",
                            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
                        },
                        {
                            "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
                            "refsource": "MISC",
                            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
                        },
                        {
                            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
                            "refsource": "CONFIRM",
                            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
                        },
                        {
                            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
                            "refsource": "CONFIRM",
                            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                        },
                        {
                            "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
                            "refsource": "MISC",
                            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
                        }
                    ]
                }
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-04T21:17:30.842Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "x_refsource_MISC",
                            "x_transferred"
                        ],
                        "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-012-ultravnc-access-of-memory-location-after-end-of-buffer/"
                    },
                    {
                        "tags": [
                            "x_refsource_CONFIRM",
                            "x_transferred"
                        ],
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
                    },
                    {
                        "tags": [
                            "x_refsource_MISC",
                            "x_transferred"
                        ],
                        "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
                    },
                    {
                        "tags": [
                            "x_refsource_CONFIRM",
                            "x_transferred"
                        ],
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
                    },
                    {
                        "tags": [
                            "x_refsource_CONFIRM",
                            "x_transferred"
                        ],
                        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
                    },
                    {
                        "tags": [
                            "x_refsource_MISC",
                            "x_transferred"
                        ],
                        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
                    }
                ]
            }
        ]
    },
    "cveMetadata": {
        "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
        "assignerShortName": "Kaspersky",
        "cveId": "CVE-2019-8265",
        "datePublished": "2019-03-09T00:00:00Z",
        "dateReserved": "2019-02-12T00:00:00",
        "dateUpdated": "2024-09-16T17:07:55.620Z",
        "state": "PUBLISHED"
    },
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1"
}