    "containers": {
        "cna": {
            "affected": [
                {
                    "product": "Medtronic Conexus Radio Frequency Telemetry Protocol",
                    "vendor": "Medtronic",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "MyCareLink Monitor versions 24950 and 24952"
                        },
                        {
                            "status": "affected",
                            "version": "CareLink Monitor version 2490C"
                        },
                        {
                            "status": "affected",
                            "version": "CareLink 2090 Programmer"
                        },
                        {
                            "status": "affected",
                            "version": "Amplia CRT-D"
                        },
                        {
                            "status": "affected",
                            "version": "Claria CRT-D"
                        },
                        {
                            "status": "affected",
                            "version": "Compia CRT-D"
                        },
                        {
                            "status": "affected",
                            "version": "Concerto CRT-D"
                        },
                        {
                            "status": "affected",
                            "version": "Concerto II CRT-D"
                        },
                        {
                            "status": "affected",
                            "version": "Consulta CRT-D"
                        },
                        {
                            "status": "affected",
                            "version": "Evera ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Maximo II CRT-D and ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Mirro ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Nayamed ND ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Primo ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Protecta ICD and CRT-D"
                        },
                        {
                            "status": "affected",
                            "version": "Secura ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Virtuoso ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Virtuoso II ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Visia AF ICD"
                        },
                        {
                            "status": "affected",
                            "version": "Viva CRT-D"
                        }
                    ]
                }
            ],
            "datePublic": "2019-03-21T00:00:00",
            "descriptions": [
                {
                    "lang": "en",
                    "value": "The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device."
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-284",
                            "description": "Improper access control CWE-284",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "dateUpdated": "2019-03-26T13:36:05",
                "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
                "shortName": "icscert"
            },
            "references": [
                {
                    "name": "107544",
                    "tags": [
                        "vdb-entry",
                        "x_refsource_BID"
                    ],
                    "url": "http://www.securityfocus.com/bid/107544"
                },
                {
                    "tags": [
                        "x_refsource_CONFIRM"
                    ],
                    "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01"
                }
            ],
            "x_legacyV4Record": {
                "CVE_data_meta": {
                    "ASSIGNER": "ics-cert@hq.dhs.gov",
                    "ID": "CVE-2019-6538",
                    "STATE": "PUBLIC"
                },
                "affects": {
                    "vendor": {
                        "vendor_data": [
                            {
                                "product": {
                                    "product_data": [
                                        {
                                            "product_name": "Medtronic Conexus Radio Frequency Telemetry Protocol",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "version_value": "MyCareLink Monitor versions 24950 and 24952"
                                                    },
                                                    {
                                                        "version_value": "CareLink Monitor version 2490C"
                                                    },
                                                    {
                                                        "version_value": "CareLink 2090 Programmer"
                                                    },
                                                    {
                                                        "version_value": "Amplia CRT-D"
                                                    },
                                                    {
                                                        "version_value": "Claria CRT-D"
                                                    },
                                                    {
                                                        "version_value": "Compia CRT-D"
                                                    },
                                                    {
                                                        "version_value": "Concerto CRT-D"
                                                    },
                                                    {
                                                        "version_value": "Concerto II CRT-D"
                                                    },
                                                    {
                                                        "version_value": "Consulta CRT-D"
                                                    },
                                                    {
                                                        "version_value": "Evera ICD"
                                                    },
                                                    {
                                                        "version_value": "Maximo II CRT-D and ICD"
                                                    },
                                                    {
                                                        "version_value": "Mirro ICD"
                                                    },
                                                    {
                                                        "version_value": "Nayamed ND ICD"
                                                    },
                                                    {
                                                        "version_value": "Primo ICD"
                                                    },
                                                    {
                                                        "version_value": "Protecta ICD and CRT-D"
                                                    },
                                                    {
                                                        "version_value": "Secura ICD"
                                                    },
                                                    {
                                                        "version_value": "Virtuoso ICD"
                                                    },
                                                    {
                                                        "version_value": "Virtuoso II ICD"
                                                    },
                                                    {
                                                        "version_value": "Visia AF ICD"
                                                    },
                                                    {
                                                        "version_value": "Viva CRT-D"
                                                    }
                                                ]
                                            }
                                        }
                                    ]
                                },
                                "vendor_name": "Medtronic"
                            }
                        ]
                    }
                },
                "data_format": "MITRE",
                "data_type": "CVE",
                "data_version": "4.0",
                "description": {
                    "description_data": [
                        {
                            "lang": "eng",
                            "value": "The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device."
                        }
                    ]
                },
                "problemtype": {
                    "problemtype_data": [
                        {
                            "description": [
                                {
                                    "lang": "eng",
                                    "value": "Improper access control CWE-284"
                                }
                            ]
                        }
                    ]
                },
                "references": {
                    "reference_data": [
                        {
                            "name": "107544",
                            "refsource": "BID",
                            "url": "http://www.securityfocus.com/bid/107544"
                        },
                        {
                            "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01",
                            "refsource": "CONFIRM",
                            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01"
                        }
                    ]
                }
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-04T20:23:21.992Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "name": "107544",
                        "tags": [
                            "vdb-entry",
                            "x_refsource_BID",
                            "x_transferred"
                        ],
                        "url": "http://www.securityfocus.com/bid/107544"
                    },
                    {
                        "tags": [
                            "x_refsource_CONFIRM",
                            "x_transferred"
                        ],
                        "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01"
                    }
                ]
            }
        ]
    },
    "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2019-6538",
        "datePublished": "2019-03-25T21:26:03",
        "dateReserved": "2019-01-22T00:00:00",
        "dateUpdated": "2024-08-04T20:23:21.992Z",
        "state": "PUBLISHED"
    },
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1"
}