    "containers": {
        "cna": {
            "affected": [
                {
                    "product": "DGE-100",
                    "vendor": "Crestron",
                    "versions": [
                        {
                            "lessThanOrEqual": "1.3384.00049.001",
                            "status": "affected",
                            "version": "unspecified",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "product": "TS-1542-C",
                    "vendor": "Crestron",
                    "versions": [
                        {
                            "lessThanOrEqual": "1.3384.00049.001",
                            "status": "affected",
                            "version": "unspecified",
                            "versionType": "custom"
                        }
                    ]
                },
                {
                    "product": "DM-DGE-200-C",
                    "vendor": "Crestron",
                    "versions": [
                        {
                            "lessThanOrEqual": "1.3384.00049.001",
                            "status": "affected",
                            "version": "unspecified",
                            "versionType": "custom"
                        }
                    ]
                }
            ],
            "credits": [
                {
                    "lang": "en",
                    "value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
                }
            ],
            "datePublic": "2018-06-12T00:00:00",
            "descriptions": [
                {
                    "lang": "en",
                    "value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
                }
            ],
            "metrics": [
                {
                    "cvssV3_0": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 9.8,
                        "baseSeverity": "CRITICAL",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                        "version": "3.0"
                    }
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "cweId": "CWE-78",
                            "description": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)",
                            "lang": "en",
                            "type": "CWE"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "dateUpdated": "2018-07-10T15:57:01",
                "orgId": "9974b330-7714-4307-a722-5648477acda7",
                "shortName": "rapid7"
            },
            "references": [
                {
                    "tags": [
                        "x_refsource_CONFIRM"
                    ],
                    "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
                },
                {
                    "tags": [
                        "x_refsource_MISC"
                    ],
                    "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
                }
            ],
            "solutions": [
                {
                    "lang": "en",
                    "value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron's product pages."
                }
            ],
            "source": {
                "advisory": "R7-2018-15",
                "discovery": "EXTERNAL"
            },
            "title": "Crestron DGE-100 Console Command Injection (FIXED)",
            "x_legacyV4Record": {
                "CVE_data_meta": {
                    "AKA": "",
                    "ASSIGNER": "cve@rapid7.com",
                    "DATE_PUBLIC": "2018-06-12T10:00:00.000Z",
                    "ID": "CVE-2018-5553",
                    "STATE": "PUBLIC",
                    "TITLE": "Crestron DGE-100 Console Command Injection (FIXED)"
                },
                "affects": {
                    "vendor": {
                        "vendor_data": [
                            {
                                "product": {
                                    "product_data": [
                                        {
                                            "product_name": "DGE-100",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "affected": "<=",
                                                        "platform": "",
                                                        "version_affected": "<=",
                                                        "version_name": "",
                                                        "version_value": "1.3384.00049.001"
                                                    }
                                                ]
                                            }
                                        },
                                        {
                                            "product_name": "TS-1542-C",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "affected": "<=",
                                                        "platform": "",
                                                        "version_affected": "<=",
                                                        "version_name": "",
                                                        "version_value": "1.3384.00049.001"
                                                    }
                                                ]
                                            }
                                        },
                                        {
                                            "product_name": "DM-DGE-200-C",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "affected": "<=",
                                                        "platform": "",
                                                        "version_affected": "<=",
                                                        "version_name": "",
                                                        "version_value": "1.3384.00049.001"
                                                    }
                                                ]
                                            }
                                        }
                                    ]
                                },
                                "vendor_name": "Crestron"
                            }
                        ]
                    }
                },
                "configuration": [],
                "credit": [
                    {
                        "lang": "eng",
                        "value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
                    }
                ],
                "data_format": "MITRE",
                "data_type": "CVE",
                "data_version": "4.0",
                "description": {
                    "description_data": [
                        {
                            "lang": "eng",
                            "value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
                        }
                    ]
                },
                "exploit": [],
                "impact": {
                    "cvss": {
                        "attackComplexity": "LOW",
                        "attackVector": "NETWORK",
                        "availabilityImpact": "HIGH",
                        "baseScore": 9.8,
                        "baseSeverity": "CRITICAL",
                        "confidentialityImpact": "HIGH",
                        "integrityImpact": "HIGH",
                        "privilegesRequired": "NONE",
                        "scope": "UNCHANGED",
                        "userInteraction": "NONE",
                        "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                        "version": "3.0"
                    }
                },
                "problemtype": {
                    "problemtype_data": [
                        {
                            "description": [
                                {
                                    "lang": "eng",
                                    "value": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)"
                                }
                            ]
                        }
                    ]
                },
                "references": {
                    "reference_data": [
                        {
                            "name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553",
                            "refsource": "CONFIRM",
                            "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
                        },
                        {
                            "name": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/",
                            "refsource": "MISC",
                            "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
                        }
                    ]
                },
                "solution": [
                    {
                        "lang": "en",
                        "value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron's product pages."
                    }
                ],
                "source": {
                    "advisory": "R7-2018-15",
                    "defect": [],
                    "discovery": "EXTERNAL"
                },
                "work_around": []
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-05T05:40:50.678Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "x_refsource_CONFIRM",
                            "x_transferred"
                        ],
                        "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
                    },
                    {
                        "tags": [
                            "x_refsource_MISC",
                            "x_transferred"
                        ],
                        "url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
                    }
                ]
            }
        ]
    },
    "cveMetadata": {
        "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
        "assignerShortName": "rapid7",
        "cveId": "CVE-2018-5553",
        "datePublished": "2018-07-10T16:00:00Z",
        "dateReserved": "2018-01-12T00:00:00",
        "dateUpdated": "2024-09-16T22:20:46.752Z",
        "state": "PUBLISHED"
    },
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1"
}