    "containers": {
        "cna": {
            "affected": [
                {
                    "product": "SoMachine HVAC Programming Software",
                    "vendor": "Schneider Electric SE",
                    "versions": [
                        {
                            "status": "affected",
                            "version": "v2.1.0 for Modicon M171/M172 Controllers"
                        }
                    ]
                }
            ],
            "datePublic": "2017-05-05T00:00:00",
            "descriptions": [
                {
                    "lang": "en",
                    "value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
                }
            ],
            "problemTypes": [
                {
                    "descriptions": [
                        {
                            "description": "Buffer Overflow",
                            "lang": "en",
                            "type": "text"
                        }
                    ]
                }
            ],
            "providerMetadata": {
                "dateUpdated": "2017-06-08T09:57:01",
                "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
                "shortName": "schneider"
            },
            "references": [
                {
                    "tags": [
                        "x_refsource_CONFIRM"
                    ],
                    "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
                },
                {
                    "name": "98449",
                    "tags": [
                        "vdb-entry",
                        "x_refsource_BID"
                    ],
                    "url": "http://www.securityfocus.com/bid/98449"
                }
            ],
            "x_legacyV4Record": {
                "CVE_data_meta": {
                    "ASSIGNER": "cybersecurity@schneider-electric.com",
                    "ID": "CVE-2017-7965",
                    "STATE": "PUBLIC"
                },
                "affects": {
                    "vendor": {
                        "vendor_data": [
                            {
                                "product": {
                                    "product_data": [
                                        {
                                            "product_name": "SoMachine HVAC Programming Software",
                                            "version": {
                                                "version_data": [
                                                    {
                                                        "version_value": "v2.1.0 for Modicon M171/M172 Controllers"
                                                    }
                                                ]
                                            }
                                        }
                                    ]
                                },
                                "vendor_name": "Schneider Electric SE"
                            }
                        ]
                    }
                },
                "data_format": "MITRE",
                "data_type": "CVE",
                "data_version": "4.0",
                "description": {
                    "description_data": [
                        {
                            "lang": "eng",
                            "value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
                        }
                    ]
                },
                "problemtype": {
                    "problemtype_data": [
                        {
                            "description": [
                                {
                                    "lang": "eng",
                                    "value": "Buffer Overflow"
                                }
                            ]
                        }
                    ]
                },
                "references": {
                    "reference_data": [
                        {
                            "name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/",
                            "refsource": "CONFIRM",
                            "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
                        },
                        {
                            "name": "98449",
                            "refsource": "BID",
                            "url": "http://www.securityfocus.com/bid/98449"
                        }
                    ]
                }
            }
        },
        "adp": [
            {
                "providerMetadata": {
                    "orgId": "af854a3a-2127-422b-91ae-364da2661108",
                    "shortName": "CVE",
                    "dateUpdated": "2024-08-05T16:19:29.459Z"
                },
                "title": "CVE Program Container",
                "references": [
                    {
                        "tags": [
                            "x_refsource_CONFIRM",
                            "x_transferred"
                        ],
                        "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
                    },
                    {
                        "name": "98449",
                        "tags": [
                            "vdb-entry",
                            "x_refsource_BID",
                            "x_transferred"
                        ],
                        "url": "http://www.securityfocus.com/bid/98449"
                    }
                ]
            }
        ]
    },
    "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2017-7965",
        "datePublished": "2017-06-07T19:00:00",
        "dateReserved": "2017-04-19T00:00:00",
        "dateUpdated": "2024-08-05T16:19:29.459Z",
        "state": "PUBLISHED"
    },
    "dataType": "CVE_RECORD",
    "dataVersion": "5.1"
}