    "data_version": "4.0",
    "data_type": "CVE",
    "data_format": "MITRE",
    "CVE_data_meta": {
        "ID": "CVE-2024-33500",
        "ASSIGNER": "productcert@siemens.com",
        "STATE": "PUBLIC"
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "A vulnerability has been identified in Mendix Applications using Mendix 10 (All versions < V10.11.0), Mendix Applications using Mendix 10 (V10.6) (All versions < V10.6.9), Mendix Applications using Mendix 9 (All versions >= V9.3.0 < V9.24.22). Affected applications could allow users with the capability to manage a role to elevate the access rights of users with that role. Successful exploitation requires to guess the id of a target role which contains the elevated access rights."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-269: Improper Privilege Management",
                        "cweId": "CWE-269"
                    }
                ]
            }
        ]
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "vendor_name": "Siemens",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "Mendix Applications using Mendix 10",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "0",
                                            "version_value": "V10.11.0"
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "Mendix Applications using Mendix 10 (V10.6)",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "0",
                                            "version_value": "V10.6.9"
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "Mendix Applications using Mendix 9",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "V9.3.0",
                                            "version_value": "V9.24.22"
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                }
            ]
        }
    },
    "references": {
        "reference_data": [
            {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-540640.html",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/html/ssa-540640.html"
            }
        ]
    },
    "impact": {
        "cvss": [
            {
                "version": "3.1",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:N",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM"
            }
        ]
    }
}