    "data_version": "4.0",
    "data_type": "CVE",
    "data_format": "MITRE",
    "CVE_data_meta": {
        "ID": "CVE-2023-1709",
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "STATE": "PUBLIC"
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "\nDatalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.\n\n \n\n"
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-121: Stack-based Buffer Overflow",
                        "cweId": "CWE-121"
                    }
                ]
            }
        ]
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "vendor_name": "Siemens ",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "JT2Go",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "0",
                                            "version_value": "14.2.0.2"
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "Teamcenter Visualization",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "13.2",
                                            "version_value": "13.2.0.13"
                                        },
                                        {
                                            "version_affected": "<",
                                            "version_name": "13.3",
                                            "version_value": "13.3.0.9"
                                        },
                                        {
                                            "version_affected": "<",
                                            "version_name": "14.0",
                                            "version_value": "14.0.0.5"
                                        },
                                        {
                                            "version_affected": "<",
                                            "version_name": "14.1",
                                            "version_value": "14.1.0.7"
                                        },
                                        {
                                            "version_affected": "<",
                                            "version_name": "14.2",
                                            "version_value": "14.2.0.2"
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                },
                {
                    "vendor_name": "Datalogics",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "Library APDFL",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<=",
                                            "version_name": "0",
                                            "version_value": "v18.0.4PlusP1e"
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                }
            ]
        }
    },
    "references": {
        "reference_data": [
            {
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-11",
                "refsource": "MISC",
                "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-11"
            },
            {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-629917.html",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/html/ssa-629917.html"
            },
            {
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-164-01",
                "refsource": "MISC",
                "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-164-01"
            }
        ]
    },
    "generator": {
        "engine": "Vulnogram 0.1.0-dev"
    },
    "source": {
        "discovery": "EXTERNAL"
    },
    "work_around": [
        {
            "lang": "en",
            "supportingMedia": [
                {
                    "base64": false,
                    "type": "text/html",
                    "value": "\n<p>Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risks: </p>\n<ul><li>Avoid opening untrusted files in JT2Go and Teamcenter Visualization </li>\n</ul><p>As a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens' <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">operational guidelines for industrial security</a>,\n and to follow the recommendations in the product manuals. Additional \ninformation on industrial security by Siemens can be found at the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\">Siemens Industrial Security web page</a>. \n</p><p>For further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\">Siemens ProductCERT</a>.</p>"
                }
            ],
            "value": "Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risks: \n\n\n  *  Avoid opening untrusted files in JT2Go and Teamcenter Visualization \n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens'  operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security ,\n and to follow the recommendations in the product manuals. Additional \ninformation on industrial security by Siemens can be found at the  Siemens Industrial Security web page https://www.siemens.com/industrialsecurity . \n\n\nFor further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the  Siemens ProductCERT https://www.siemens.com/cert/advisories .\n\n"
        },
        {
            "lang": "en",
            "supportingMedia": [
                {
                    "base64": false,
                    "type": "text/html",
                    "value": "\n<p>Datalogics recommends users to update to APDFL v18.0.4PlusP1g. <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.datalogics.com/datalogics-contact-us\">Contact Datalogics</a>&nbsp;for more information on obtaining this update.</p><p>For more information, refer to <a target=\"_blank\" rel=\"nofollow\" href=\"https://dev.datalogics.com/adobe-pdf-library/release-notes-adobe-pdf-library-v-18/\">Datalogic\u2019s release notes</a>.</p>\n\n<br>"
                }
            ],
            "value": "Datalogics recommends users to update to APDFL v18.0.4PlusP1g.  Contact Datalogics https://www.datalogics.com/datalogics-contact-us \u00a0for more information on obtaining this update.\n\nFor more information, refer to  Datalogic\u2019s release notes https://dev.datalogics.com/adobe-pdf-library/release-notes-adobe-pdf-library-v-18/ .\n\n\n\n\n"
        }
    ],
    "solution": [
        {
            "lang": "en",
            "supportingMedia": [
                {
                    "base64": false,
                    "type": "text/html",
                    "value": "\n<div>Siemens has released updates for the affected products and recommends updating to the latest versions:</div><ul><li>JT2Go: <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\">Update to V14.2.0.2</a> or later version</li><li>Teamcenter Visualization V13.2: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.2.0.13</a>&nbsp; or later version </li><li>Teamcenter Visualization V13.3: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.3.0.9</a>&nbsp; or later version </li><li>Teamcenter Visualization V14.0: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.0.0.5</a>&nbsp; or later version </li><li>Teamcenter Visualization V14.1: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.1.0.7</a>&nbsp; or later version </li><li>Teamcenter Visualization V14.2: <a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.2.0.2</a>&nbsp; or later version \n\n</li></ul>"
                }
            ],
            "value": "Siemens has released updates for the affected products and recommends updating to the latest versions:\n\n  *  JT2Go:  Update to V14.2.0.2 https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html  or later version\n  *  Teamcenter Visualization V13.2:  Update to V13.2.0.13 https://support.sw.siemens.com/ \u00a0 or later version \n  *  Teamcenter Visualization V13.3:  Update to V13.3.0.9 https://support.sw.siemens.com/ \u00a0 or later version \n  *  Teamcenter Visualization V14.0:  Update to V14.0.0.5 https://support.sw.siemens.com/ \u00a0 or later version \n  *  Teamcenter Visualization V14.1:  Update to V14.1.0.7 https://support.sw.siemens.com/ \u00a0 or later version \n  *  Teamcenter Visualization V14.2:  Update to V14.2.0.2 https://support.sw.siemens.com/ \u00a0 or later version \n\n\n\n\n"
        }
    ],
    "credits": [
        {
            "lang": "en",
            "value": "Michael Heinzl reported this vulnerability to Siemens. "
        }
    ],
    "impact": {
        "cvss": [
            {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
            },
            {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",