    "data_version": "4.0",
    "data_type": "CVE",
    "data_format": "MITRE",
    "CVE_data_meta": {
        "ID": "CVE-2022-3161",
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "STATE": "PUBLIC"
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "The APDFL.dll contains a memory corruption vulnerability while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-119",
                        "cweId": "CWE-119"
                    }
                ]
            }
        ]
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "vendor_name": "Siemens\u00a0",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "JT2Go",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "0",
                                            "version_affected": "="
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "Teamcenter Visualization V13.3",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "0",
                                            "version_affected": "="
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "Teamcenter Visualization V14.0",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "0",
                                            "version_affected": "="
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "Teamcenter Visualization V14.1",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_value": "0",
                                            "version_affected": "="
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                }
            ]
        }
    },
    "references": {
        "reference_data": [
            {
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15",
                "refsource": "MISC",
                "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15"
            },
            {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html"
            },
            {
                "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json"
            }
        ]
    },
    "generator": {
        "engine": "Vulnogram 0.1.0-dev"
    },
    "source": {
        "discovery": "EXTERNAL"
    },
    "work_around": [
        {
            "lang": "en",
            "supportingMedia": [
                {
                    "base64": false,
                    "type": "text/html",
                    "value": "\n<p>Siemens identified the following specific workaround and mitigation user can apply to reduce risk: </p>\n\n<ul><li>Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.</li>\n</ul><p>As a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens' <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\">operational guidelines for industrial security</a></p> and following the recommendations in the product manuals. Siemens also provides <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\">additional information on industrial security</a>.<br>\nFor further inquiries on security vulnerabilities in Siemens products, users should contact <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\">Siemens</a>. <br>\nFor more information, see the associated Siemens security advisory SSA-360681 in <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\">HTML </a>and <a target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\">CSAF</a>.\n\n<br>"
                }
            ],
            "value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n  *  Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens'  operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides  additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact  Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in  HTML  https://cert-portal.siemens.com/productcert/html/ssa-360681.html and  CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n"
        }
    ],
    "solution": [
        {
            "lang": "en",
            "supportingMedia": [
                {
                    "base64": false,
                    "type": "text/html",
                    "value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:<br><ul><li><span style=\"background-color: var(--wht);\">JT2Go: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">.&nbsp;<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V13.3: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V13.3.0.8 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.0: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.0.0.4 or later version</a><span style=\"background-color: var(--wht);\">.<br></span></li><li><span style=\"background-color: var(--wht);\">Teamcenter Visualization V14.1: </span><a target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\">Update to V14.1.0.5 or later version</a><span style=\"background-color: var(--wht);\">.</span></li></ul>"
                }
            ],
            "value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n  *  JT2Go:  Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n  *  Teamcenter Visualization V13.3:  Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n  *  Teamcenter Visualization V14.0:  Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n  *  Teamcenter Visualization V14.1:  Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n"
        }
    ],
    "credits": [
        {
            "lang": "en",
            "value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0"
        }
    ],
    "impact": {
        "cvss": [
            {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
            }
        ]
    }
}