    "CVE_data_meta": {
        "ASSIGNER": "cybersecurity@schneider-electric.com",
        "DATE_PUBLIC": "2022-07-12T11:00:00.000Z",
        "ID": "CVE-2022-34760",
        "STATE": "PUBLIC"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "OPC UA Modicon Communication Module",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "BMENUA0100",
                                            "version_value": "V1.10"
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "X80 advanced RTU Communication Module",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "=",
                                            "version_name": "BMENOR2200H",
                                            "version_value": "V1.0 "
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "Schneider Electric"
                }
            ]
        }
    },
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "A CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)"
            }
        ]
    },
    "generator": {
        "engine": "Vulnogram 0.0.9"
    },
    "impact": {
        "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
        }
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": " CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop')"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "refsource": "MISC",
                "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf",
                "name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
            }
        ]
    },
    "source": {
        "discovery": "UNKNOWN"
    }
}