    "CVE_data_meta": {
        "ASSIGNER": "cybersecurity@hitachienergy.com",
        "DATE_PUBLIC": "2022-09-06T14:30:00.000Z",
        "ID": "CVE-2022-29492",
        "STATE": "PUBLIC",
        "TITLE": "A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open."
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "MicroSCADA X SYS600",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "=",
                                            "version_value": "10"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "10.1"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "10.1.1"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "10.2"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "10.2.1"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "10.3"
                                        },
                                        {
                                            "version_affected": "=",
                                            "version_value": "10.3.1"
                                        }
                                    ]
                                }
                            },
                            {
                                "product_name": "MicroSCADA Pro SYS600",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<=",
                                            "version_value": "9.2 FP2 Hotfix 4"
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "Hitachi Energy"
                }
            ]
        }
    },
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*"
            }
        ]
    },
    "generator": {
        "engine": "Vulnogram 0.0.9"
    },
    "impact": {
        "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
        }
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-20 Improper Input Validation"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch",
                "refsource": "CONFIRM",
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106&LanguageCode=en&DocumentPartId=&Action=Launch"
            }
        ]
    },
    "solution": [
        {
            "lang": "eng",
            "value": "Remediated in SYS600 10.4 \nFor MicroSCADA Pro SYS600  - Upgrade to at least SYS600 version 10.4.\nFor MicroSCADA X SYS600  - Update to at least SYS600 version 10.4."
        }
    ],
    "source": {
        "discovery": "INTERNAL"
    },
    "work_around": [
        {
            "lang": "eng",
            "value": "Apply general mitigation factors as specify in the advisory."
        }
    ]
}