    "data_version": "4.0",
    "data_type": "CVE",
    "data_format": "MITRE",
    "CVE_data_meta": {
        "ID": "CVE-2022-29034",
        "ASSIGNER": "productcert@siemens.com",
        "STATE": "PUBLIC"
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code.\r\n\r\nThis could allow attackers to perform reflected cross-site scripting (XSS) attacks."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
                        "cweId": "CWE-79"
                    }
                ]
            }
        ]
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "vendor_name": "Siemens",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "SINEMA Remote Connect Server",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "0",
                                            "version_value": "V3.1"
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                }
            ]
        }
    },
    "references": {
        "reference_data": [
            {
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf"
            },
            {
                "url": "http://seclists.org/fulldisclosure/2022/Jun/35",
                "refsource": "MISC",
                "name": "http://seclists.org/fulldisclosure/2022/Jun/35"
            },
            {
                "url": "http://packetstormsecurity.com/files/167554/SIEMENS-SINEMA-Remote-Connect-3.0.1.0-01.01.00.02-Cross-Site-Scripting.html",
                "refsource": "MISC",
                "name": "http://packetstormsecurity.com/files/167554/SIEMENS-SINEMA-Remote-Connect-3.0.1.0-01.01.00.02-Cross-Site-Scripting.html"
            },
            {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html"
            }
        ]
    },
    "impact": {
        "cvss": [
            {
                "version": "3.1",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM"
            }
        ]
    }
}