    "CVE_data_meta": {
        "ASSIGNER": "productsecurity@jci.com",
        "DATE_PUBLIC": "2022-10-25T21:14:00.000Z",
        "ID": "CVE-2021-36206",
        "STATE": "PUBLIC",
        "TITLE": "CEVAS"
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "product": {
                        "product_data": [
                            {
                                "product_name": "CEVAS",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "<",
                                            "version_name": "all versions prior to 1.01.46",
                                            "version_value": "1.01.46"
                                        }
                                    ]
                                }
                            }
                        ]
                    },
                    "vendor_name": "Johnson Controls"
                }
            ]
        }
    },
    "credit": [
        {
            "lang": "eng",
            "value": "Christian Vierschilling and Caroline Moesler reported this vulnerability to Johnson Controls, Inc."
        }
    ],
    "data_format": "MITRE",
    "data_type": "CVE",
    "data_version": "4.0",
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "All versions of CEVAS prior to 1.01.46 do not sufficiently validate user-controllable input and could allow a user to bypass authentication and retrieve data with specially crafted SQL queries."
            }
        ]
    },
    "generator": {
        "engine": "Vulnogram 0.0.9"
    },
    "impact": {
        "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
        }
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
                    }
                ]
            }
        ]
    },
    "references": {
        "reference_data": [
            {
                "name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories",
                "refsource": "CONFIRM",
                "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
            },
            {
                "name": "ICS-CERT Advisory",
                "refsource": "CERT",
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-05"
            }
        ]
    },
    "solution": [
        {
            "lang": "eng",
            "value": "Upgrade CEVAS to version 1.01.46. Contact CKS for the upgrade."
        }
    ],
    "source": {
        "discovery": "EXTERNAL"
    }
}