    "data_version": "4.0",
    "data_type": "CVE",
    "data_format": "MITRE",
    "CVE_data_meta": {
        "ID": "CVE-2019-18337",
        "ASSIGNER": "productcert@siemens.com",
        "STATE": "PUBLIC"
    },
    "description": {
        "description_data": [
            {
                "lang": "eng",
                "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an authentication bypass\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\n\nA remote attacker with network access to the CCS server could\nexploit this vulnerability to read the CCS users database, including\nthe passwords of all users in obfuscated cleartext."
            }
        ]
    },
    "problemtype": {
        "problemtype_data": [
            {
                "description": [
                    {
                        "lang": "eng",
                        "value": "CWE-287: Improper Authentication",
                        "cweId": "CWE-287"
                    }
                ]
            }
        ]
    },
    "affects": {
        "vendor": {
            "vendor_data": [
                {
                    "vendor_name": "Siemens",
                    "product": {
                        "product_data": [
                            {
                                "product_name": "Control Center Server (CCS)",
                                "version": {
                                    "version_data": [
                                        {
                                            "version_affected": "=",
                                            "version_value": "All versions < V1.5.0"
                                        }
                                    ]
                                }
                            }
                        ]
                    }
                }
            ]
        }
    },
    "references": {
        "reference_data": [
            {
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
            },
            {
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf",
                "refsource": "MISC",
                "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
            }
        ]
    },
    "impact": {
        "cvss": [
            {
                "version": "3.1",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL"
            }
        ]
    }
}